Fitting The Coaxial Flue; Horizontal) - Ariston GENUS 30 Plus Installation And Servicing Instructions

Type c boilers
Table of Contents

Advertisement

W
!!
ARNING
The exhaust gas ducts must not be in contact with or
close to inflammable material and should not pass
through building structures or walls made of inflammable
material.
When replacing an old appliance, the flue must be
changed.
I
!!
MPORTANT
Ensure that the flue is not blocked.
Ensure that the flue is assembled correctly, is secure and
is free of leaks.
Ø 60/100 mm
F
. 11.4
IG
P1
P2
OFF
ON
11.2 Fitting the coaxial flue (Ø 60/100

Horizontal)

F
. 11.5
IG
W
!!
ARNING
Consult the table on Page 28, to see if a restrictor is
required for the type of flue system being used. Should it
be necessary to fit the restrictor, it must be placed in the air
inlet connection on the boilers exhaust terminal.
L max = 3 m
The minimum acceptable spacing from the terminal to
obstructions and ventilation openings are specified in Fig. 11.1
The boiler is designed to be connected to a coaxial flue
discharge system.
The boiler must only be installed with a flue supplied by the
boiler manufacturer.
These kits are supplied separately to the appliance in order to
respond to different installation solutions. For more information
with regard to the inlet/outlet accessories consult the flue guide
and the following instructions. The boiler is predisposed for the
connection to a concentric air intake and exhaust duct system.
Flue
Clamp
C
:
ONTENTS
1
S
O-R
(60mm)
X
ILICONE
ING
1
E
(90
)
O
X
LBOW
2
W
S
(I
& E
X
ALL
EALS
NTERNAL
1
A
F
P
X
LUMINIUM
LUE
IPE INCLUDING
2
F
C
X
LUE
LAMPS
4
S
X
CREWS
2
R
F
P
X
ECTANGULAR
OAM
ADS
Once the boiler has been positioned on the wall, insert the
elbow into the socket and rotate to the required position.
It is possible to rotate the elbow 360
Using the flue clamps, pads and screws supplied (Figs 11.4 &
11.5) secure the elbow to the boiler.
The 1 metre horizontal flue kit (705958) supplied is suitable for
an exact X dimension of 823mm, and the 750mm horizontal
flue kit (705785) is suitable for an exact X dimension of
573mm.
Measure the distance from the face of the external wall to the
face of the flue elbow (X - Fig 11.4), add 22 mm to this
measurement, you now have the total length of flue required
(including the terminal), this figure must now be subtracted
from 860mm, you now have the total amount to be cut from the
plain end of the flue.
Cut the flue to the required length ensuring that the distance
between the inner and the outer flue is maintained (Fig 11.6).
Maximum Lenght = 3 m
Minimum Lenght = 370 mm
X
95 mm
100 mm
)
XTERNAL
T
(1
- 60/100)
ERMINAL
METRE
on its vertical axis.
O
107 mm
:
NOTE
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents