Alarm; Alarm Connections; Connect On Alarm; Number Of Destination Ip Address - Bosch FW5.50 Software Manual

Camera browser interface
Table of Contents

Advertisement

Camera Browser Interface
11

Alarm

11.1

Alarm Connections

In the event of an alarm, the camera can automatically connect
to a pre-defined IP address. The camera can contact up to ten
IP addresses in the order listed until a connection is
established.
11.1.1

Connect on alarm

Select On so that the camera automatically connects to a pre-
defined IP address in the event of an alarm. Select Follows
input 1 so that the device maintains the connection for as long
as an alarm exists.
11.1.2

Number of destination IP address

Specify the numbers of the IP addresses to be contacted in the
event of an alarm. The device contacts the remote locations one
after the other in the numbered sequence until a connection is
made.
11.1.3

Destination IP address

For each number, enter the corresponding IP address for the
desired remote station.
11.1.4

Destination password

If the remote station is password protected, enter the
password here.
Only ten passwords can be defined here. Define a general
password if more than ten connections are required, for
example, when connections are initiated by a controlling
system such as the Bosch Video Client or the Bosch Video
Management System. The camera connects to all remote
stations protected by the same general password. To define a
general password:
1.
2.
Bosch Security Systems
Select 10 in the Number of destination IP address list
box.
Enter 0.0.0.0 in the Destination IP address field.