3-6 ESX Server Operation and Configuration

Evaluate Start and Stop of CPU Modules

This section describes how to confirm the continuous system operation after stopping one of the
CPU modules.
1.
Confirm that the CPU modules are duplicated.
To check if the CPU modules are duplicated, see the status LEDs of the CPU modules.
[Indications of status LEDs when CPU modules are duplicated]
1
CPU/IO module status LED1
2
CPU/IO module status LED2
2.
Use the ft server utility to stop the operation of the CPU module to be removed.
Move to the directory where the ft utility of NEC ESMPRO Agent is installed.
# cd /opt/nec/esmpro_sa/bin/
Start the ft server utility.
# ./ESMftcutil
The screen of the ft server utility will appear.
LED
CPU module 0
(Operating)
-
Green
CPU module 1
(Operating)
-
Green