Maytag MDG75MNV Installation Manual
Maytag MDG75MNV Installation Manual

Maytag MDG75MNV Installation Manual

1,000 cfm / phase 7 with s.a.f.e. system
Hide thumbs Also See for MDG75MNV:

Advertisement

MDG75PNH and MDG75MNV
Installation Manual
1,000 CFM / Phase 7 with S.A.F.E. System
WARNING: For your safety the information
in this manual must be followed to
minimize the risk of fire or explosion and
to prevent property damage, personal
injury or death.
— Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch;
do not use any phone in your
building.
Clear the room, building or area of
all occupants.
Immediately call your gas supplier
from a neighbor's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
— Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.
AVERTISSEMENT: Assurez-vous de bien
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d'incendie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
—Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides
inflammables à proximité de cet
appareil ou de tout autre appareil.
—QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne
pas vous servir des téléphones se
trouvant dans le bâtiment.
Évacuez la pièce, le bâtiment ou la
zone.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
—L'installation et l'entretien doivent être
assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.
RETAIN THESE
INSTRUCTIONS IN A
SAFE PLACE FOR
FUTURE REFERENCE
Part No. 113394-8

Advertisement

Table of Contents
loading

Summary of Contents for Maytag MDG75MNV

  • Page 1 MDG75PNH and MDG75MNV Installation Manual 1,000 CFM / Phase 7 with S.A.F.E. System WARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury or death.
  • Page 2 Retain This Manual In A Safe Place For Future Reference This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of efficient, trouble free, and most importantly safe operation. ONLY qualified technicians should service this equipment.
  • Page 3: For Your Safety

    State of California Proposition 65 Warnings: WARNING: This product contains a chemical known to the State of California to cause cancer. WARNING: This product contains a chemical known to the State of California to cause birth defects or other reproductive harm. YOU MUST DISCONNECT AND LOCK OUT THE ELECTRIC SUPPLY AND THE GAS SUPPLY BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUSTING, INSTALLATION, OR...
  • Page 4 WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY OR FIRE COULD RESULT. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer.
  • Page 5: Table Of Contents

    Table of Contents SECTION I SAFETY PRECAUTIONS ... 3 SECTION II SPECIFICATIONS ... 5 A. Specifications ... 5 B. Component Identification ... 7 SECTION III INSTALLATION PROCEDURES ... 9 A. Location Requirements ... 9 B. Unpacking/Setting Up ... 10 C. Dryer Enclosure Requirements ... 11 D.
  • Page 6 SECTION VII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS ... 36 SECTION VIII MANUAL RESET BURNER HI-LIMIT INSTRUCTIONS ... 38 A. Phase 7 ... 38 B. Dual Timer ... 38 SECTION IX SENSOR ACTIVATED FIRE EXTINGUISHING (S.A.F.E.) SYSTEM ... 39...
  • Page 7: Safety Precautions

    WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed.
  • Page 8 WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard. 7. A program should be established for the inspection and cleaning of lint in the burner area, exhaust ductwork, and area around the back of the dryer.
  • Page 9: Specifications

    A. SPECIFICATIONS ’ 0 ’ 0 ’ 8 ’ 3 . F . Shaded areas are stated in metric equivalents ALL reversing dryers are supplied with two (2) 3-phase (3ø) motors standard: a 1/2 hp (0.37 kW) blower motor and a 1/2 hp (0.37 kW) drive motor. NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
  • Page 10 Specifications – Gas NOTE: The manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Maytag Co. 113394 - 8...
  • Page 11: Component Identification

    B. COMPONENT IDENTIFICATION 1. Dryer Front View Illus. No. Description Controls Control (top access) Door Assembly Main Door Assembly Lint Compartment Area (lint screen located behind lint door or left sidewall) Data Label and Installation Label 113394 - 8 Maytag Co.
  • Page 12 2. Dryer Rear View Illus. No. Description Heating Unit Electric Service Relay Box Basket (tumbler) Bearing Mount Assembly Idler Bearing Mount Assembly Blower Motor Assembly (for reversing models only) Leveling Legs (rear) Basket (tumbler) (drive) Motor Assembly Dryer Exhaust Maytag Co. 113394 - 8...
  • Page 13: Installation Procedures

    INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.1- LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70-LATEST EDITION (National Electrical Code) or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing) or Canadian Electrical Codes Parts 1 &...
  • Page 14: Unpacking/Setting Up

    10. The dryer must be installed with provisions for adequate combustion and make-up air supply. CAUTION: This dryer produces combustible lint and must be exhausted to the outdoors. Every 6 months, inspect the exhaust ducting and remove any lint buildup. IMPORTANT: Dryer must be installed in a location/environment, which the ambient temperature remains between 40°...
  • Page 15: Dryer Enclosure Requirements

    C. DRYER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12-inches (30.48 cm), 18-inches (45.72 cm) or more is recommended for ease of installation, maintenance, and service above the dryer’s outer top, except along the front of the dryer which may be partially closed in if desired.
  • Page 16: Fresh Air Supply Requirements

    D. FRESH AIR SUPPLY REQUIREMENTS When the dryer is operating, it draws in room air, heats it, passes this air through the basket (tumbler), and exhausts it out of the building. Therefore, the room air must be continually replenished from the outdoors. If the make-up air is inadequate, drying time and drying efficiency will be adversely affected.
  • Page 17: Exhaust Requirements

    E. EXHAUST REQUIREMENTS 1. General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure which results in slow drying, increased use of energy, overheating of the dryer, and shutdown of the burner by the airflow (sail) switches, burner hi-limits, or basket (tumbler) hi-heat thermostats.
  • Page 18 IMPORTANT: Exhaust back pressure measured by a manometer in the exhaust duct must be no less than 0 and must not exceed 0.7 inches (1.74 mb) of water column (W.C.). NOTE: When the exhaust ductwork passes through a wall, ceiling, or roof made of combustible materials, the opening must be 2-inches (5.08 cm) larger than the duct (all the way around).
  • Page 19 IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits noted in this manual, a professional heating, ventilating, and air-conditioning (HVAC) firm should be consulted for proper venting information. ALL ductwork should be smooth inside with no projections from sheet metal screws or other obstructions, which will collect lint.
  • Page 20 3. Multiple (Common) Dryer Venting IMPORTANT: For extended ductwork runs, the cross section area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits noted in this manual, a professional heating, ventilating, and air-conditioning (HVAC) firm should be consulted for proper venting information.
  • Page 21 IMPORTANT VENTING REMINDERS 1. Ductwork size and installation should be done by a qualified professional. 2. The dryer must be exhausted to the outdoors. 3. Ductwork should be routed as short as possible to the outdoors with as few elbows as possible. 4.
  • Page 22: Electrical Information

    F. ELECTRICAL INFORMATION 1. Electrical Requirements ALL electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL electrical connections, materials, and workmanship must conform to the applicable requirements of the National Electrical Code ANSI/NFPA NO.
  • Page 23 2. Electrical Service Specifications NON-REVERSING (GAS) ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER) IMPORTANT: 208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage. NOTES: When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY . Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes to listed appliance amp draw data.
  • Page 24 3. Grounding A ground (earth) connection must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 &...
  • Page 25 FOR 110V APPLICATIONS FOR 208-240V APPLICATIONS A ground lug is provided in the rear electrical box to connect your service ground. b. 3-Phase (3ø) Wiring Connections/Hookup The electrical connections on ALL 3-phase (3ø) dryers are made into the rear service box located at the upper left area of the dryer.
  • Page 26: Gas Information

    G. GAS INFORMATION It is your responsibility to have ALL plumbing connections made by a qualified professional to ensure that the gas plumbing installation is adequate and conforms to local and state regulations or codes. In the absence of such codes, ALL plumbing connections, materials, and workmanship must conform to the applicable requirements of the National Fuel Gas Code ANSI Z223.1-LATEST EDITION, or in Canada, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION.
  • Page 27 2. Technical Gas Data a. Gas Specifications Manifold Pressure* 3.5 inches W.C. 6.0 - 12.0 inches W.C. 14.92 - 29.9 mb In-Line Pressure Shaded areas are stated in metric equivalents * Measured at outlet side of gas valve pressure tap when gas valve is on. b.
  • Page 28 3. Piping Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LATEST EDITION, or in Canada, CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (Liquid Propane [L.P.] Gas) or LATEST EDITION (for General Installation and Gas Plumbing), as well as local codes and ordinances and must be done by a qualified professional.
  • Page 29 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 3/4-inch (19.05 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.0 inches (29.9 mb) of water column (W.C.) pressure.
  • Page 30: Preparation For Operation/Start-Up

    H. PREPARATION FOR OPERATION/START-UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “CAUTION,” “WARNING,” and “DIRECTION” labels attached to the dryer. 2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label. In the case of 208 VAC or 240 VAC, the supply voltage must match the electric service specifications of the data exactly.
  • Page 31: Preoperational Tests

    I. PREOPERATIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory. However, a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions. 1.
  • Page 32 NOTE: To check for proper sail switch operation, open the main door and while holding main door switch plunger in, start dryer. Dryer should start but heat circuit should not be activated (on). If the heat system is activated, the sail switch is improperly adjusted and must be adjusted by bending the actuator arm of the sail switch toward the burner box.
  • Page 33: Preoperational Instructions

    J. PREOPERATIONAL INSTRUCTIONS 1. To start the dryer: Microprocessor Controller (Computer) Dryers a. Light emitting diode (L.E.D.) display will read “READY” (meaning no cycle in progress). b. Press the letter on the keyboard (touch pad) corresponding to the cycle desired (i.e., key “E”) and the dryer will then start.
  • Page 34: Shutdown Instructions

    REVERSING TIMER SPIN/DWELL ADJUSTMENTS Timer models have an electronic reversing timer in the electrical service box, which is located in the upper left rear area of the dryer. Both the Dwell (stop) Time and the basket (tumbler) Spin Time are adjustable by mode selection switches located on the electronic timer (as noted in the illustration below).
  • Page 35: Service/Parts Information

    SERVICE/PARTS INFORMATION A. SERVICE Service must be performed by a qualified trained technician, service agency, or gas supplier. If service is required, contact the Maytag dealer from whom the equipment was purchased. If the dealer cannot be contacted or is unknown, contact the Maytag Co. for a dealer in your area. NOTE: When contacting the Maytag Co., be sure to give them the correct model number and serial number so that your inquiry is handled in an expeditious manner.
  • Page 36: Routine Maintenance

    ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location. Maximum operating efficiency is dependent upon proper air circulation.
  • Page 37: Adjustments

    90 DAYS Inspect and remove lint accumulation in customer furnished exhaust ductwork system and from dryer’s internal exhaust ducting. WARNING: THE ACCUMULATION OF LINT IN THE EXHAUST DUCTWORK CAN CREATE A POTENTIAL FIRE HAZARD. WARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILATION AIR.
  • Page 38: Lint Drawer Removal

    D. LINT DRAWER REMOVAL To remove the lint drawer from the dryer pull drawer out approximately halfway. Rotate/move lint drawer stop hinge (refer to the illustration below) downward and pull drawer out. IMPORTANT: After replacing the lint drawer back into the dryer, be sure to rotate/move hinge back to the upward stop position.
  • Page 39: Data Label Information

    DATA LABEL INFORMATION When contacting the Maytag dealer, or the Maytag Co., certain information is required to ensure proper service/parts information. This information is on the data label affixed to the upper left side panel area behind the top control (access) door. When contacting Maytag Co., please have the model number and serial number available.
  • Page 40: Procedure For Functional Check

    SECTION VII PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a. Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer. b. Start the drying cycle by pressing any of the preset cycles in letters A-F. c.
  • Page 41 2. For Models with Direct Spark Ignition (DSI) Module (Type I) Theory of Operation: Start the drying cycle. When the gas burner ignites within the chosen trial for ignition time (6-seconds), the flame sensor detects gas burner flame and signals the DSI module to keep the gas valve open as long as there is a call for heat.
  • Page 42: Manual Reset Burner Hi-Limit Instructions

    SECTION VIII MANUAL RESET BURNER HI-LIMIT INSTRUCTIONS A. PHASE 7 This dryer was manufactured with a manual reset burner hi-limit thermostat, which is monitored by the Phase 7 computer. If the burner hi-limit is open prior to the start of the drying cycle, the dryer will start momentarily and then shut down, the Phase 7 computer will display “BURNER HIGH LIMIT FAULT”...
  • Page 43: Sensor Activated Fire Extinguishing (S.a.f.e.) System

    FIRE EXTINGUISHING (S.A.F.E.) SYSTEM S.A.F.E. System In Action The exclusive Sensor Activated Fire Extinguishing (S.A.F.E.) system will extinguish fires that may start in the drying basket (tumbler). A series of sensors positioned throughout the basket (tumbler) and interfaced with the microprocessor controller (computer) will trigger the S.A.F.E.
  • Page 44 INSTALLATION 1. Requirements The S.A.F.E. system must be supplied with a minimum water pipe size of 1/2” and be provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure. For use of optional manual bypass, a second source with the same piping and pressure requirements is required.
  • Page 45 Typical Water Supply OPTIONAL MANUAL BYPASS Provisions are made in the dryer S.A.F.E. system for the installation of an optional manual bypass. Depending on the model dryer, the connections for the manual bypass are made at the “T” or “three way” fitting located in the outlet supply side of the water solenoid valve.
  • Page 46: System Reset

    WARNING: If the water in the supply line or water solenoid valve freezes, the S.A.F.E. system will be INOPERATIVE!! The manual ball cock shutoff valve must be located outside of the dryer at a distance from the dryer where it is easily accessible.
  • Page 47 S.A.F.E. System Water Valve Check The operation of the water solenoid valve can be tested to ensure that the water supply system and valve are functional. Before attempting a system check, be sure that ALL water supply shutoff valves to the dryer are in the OPEN position;...
  • Page 48 S.A.F.E. System Diagnostics Messages OPEN THERMISTOR PROBE – This message indicates that the S.A.F.E. system thermistor probe either is not connected or is damaged. If this condition is detected, the Phase 7 non-coin control will immediately enter S.A.F.E. SYSTEM DISABLED mode. SHORTED THERMISTOR PROBE –...
  • Page 49 NOTES _________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ 113394 - 8 Maytag Co.
  • Page 50 Part No. 113394 8 - 10/30/08 - 25...