NAPCO Gemini GEM-P1632 Installation Instructions Manual

NAPCO Gemini GEM-P1632 Installation Instructions Manual

Control panel/communicator

Advertisement

HARDWIRE
CONTROL PANEL/COMMUNICATOR
For use with "Classic" keypads (GEM-RP1CAe2, GEM-RP2ASe2, GEM-RP3DGTL and GEM-RP4RFC/GEM-RP4C)
and with "K Series" keypads (GEM-K1CA, GEM-K2AS, GEM-K3DGTL, and GEM-K4RF/GEM-K4)
G E M I N I
SYSTEM READY
01/01/03
R
1
B
4
C
7
C O M P U T E R I Z E D S E C U R I T Y S Y S T E M
"K Series" GEM-K1CA
GEMINI
32
A
1 2
R
B
4
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
"K Series" GEM-K3DGTL
© Napco 2003
R
G E M - P 1 6 3 2
12:00 AM
NEXT/YES
U
P
2
3
PRIOR/NO
Q
5
6
AREA
8
9 0
G
SYSTEM ARMED
ENT A1
01/01/97 12:00AM
INTERIOR
BYPASS
FIRE/TBL
SYS TBL
CHIME
NEXT/YES
3
E
D
PRIOR/NO
5 6
F
AREA
G
R
INSTALLATION
INSTRUCTIONS
WIRELESS
GEMINI
SYSTEM ARMED
READY
01/01/97
12:00AM
READY
AC ON
AC ON
A
1 2
3
R
D
B
4
5 6
C
7 8 9 0
COMPUTERIZED SECURITY SYSTEM
"K Series" GEM-K2AS
"K Series" GEM-K4RF
NEXT/YES
E
PRIOR/NO
F
AREA
G
R
WI808F 8/03

Advertisement

Table of Contents
loading

Summary of Contents for NAPCO Gemini GEM-P1632

  • Page 1 "K Series" GEM-K1CA "K Series" GEM-K2AS GEMINI SYSTEM ARMED ENT A1 01/01/97 12:00AM INTERIOR BYPASS FIRE/TBL SYS TBL CHIME NEXT/YES PRIOR/NO AREA 7 8 9 0 COMPUTERIZED SECURITY SYSTEM "K Series" GEM-K3DGTL "K Series" GEM-K4RF © Napco 2003 WI808F 8/03...
  • Page 2: Important Notice

    The following changes have been made to this manual (WI808F) since the previous edition (WI808E). Page 2, "Important Notice", deleted NOTE which begins, "Typically, most versions of the GEM-P1632 control panel can be upgraded…" and ends, "...affixed to the GEM-P1632 circuit board."...
  • Page 3: Table Of Contents

    WIRING LEGEND ........... 44 Siren/Bell Output ............. 13 KEYPAD PROGRAMMING MODES ...... 45 Auxiliary Power ............13 GEM-P1632 WIRING DIAGRAM ......50 PGM Outputs ............13 CP-01 QUICK REFERENCE CHART ..... 51 Remote Bus ............14 FACTORY DEFAULT DESCRIPTION ....53 Earth Ground ............
  • Page 4: Introduction

    Conventional LEDs and a sounder are also provided for annunciation. Data may be quickly and easily downloaded to the control panel using a PC-compatible computer with Napco's PCD- Windows Quickloader software and PCI2000 computer interface. Or, the panel may be programmed using the keypad in its secondary mode of operation.
  • Page 5: Important Note

    False Alarm Reduction Control Panel-01 Standard (SIA FAR CP-01). IMPORTANT NOTE This manual supports the keypad programming of the GEM-P1632 control panel with the NAPCO "classic" GEM- RP1CAe2, GEM-RP2ASe2, and GEM-RP3DGTL keypads as well as the GEM-K1CA, GEM-K2AS, and GEM-K3DGTL "K Series"...
  • Page 6: Specifications

    Alarm current can be increased by reducing standby current by the same amount. * Commercial Burglary specifications not evaluated by U.L. RESIDENTIAL FIRE PROGRAMMING OPTION: Refer to GEM-P1632 Programming Instructions (WI897 and WI 1148) for programming information. This option changes the operation of the power supply in alarm conditions to optimize performance.
  • Page 7: Ordering Information

    WL1: Wire Assembly with Lug Connector, 20” VERI-PHONE: Two-Way Voice/Listen-In Module* System Components PCD3000: Downloading Software (for DOS) for IBM PC- GEM-P1632: Residential UL-Listed Burg and Fire Control Compatible* Panel. PCD-Windows: Downloading Software (for Windows) for GEM-RP1CAe2: 32-Character LCD Burg & Fire Keypad IBM PC-Compatible* with 4 EOL Zones.
  • Page 8: Summary Of Ul Requirements

    Keypad Expansion (EZM) Zones are not to be used as fire zones Keypad Auxiliary is not to be selected The GEM-K Series Keypads must have the indicators printed on the face label (Fire, Police and Auxiliary) covered by a supplied label if not in use. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 9: Installation

    Then, using hardware suitable for the mounting surface, add one or two screws at the right side of the keypad case directly into the wall to ensure a secure installation. Note: Do not overtighten the screws! Uneven walls may cause the keypad case to distort. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 10: Wiring

    CAUTION: Do not run telephone wiring near speaker wires; do not run keypad wiring with loop wiring. Adding Expansion Zones GEM-P1632-Series control panels will handle up to 16 zones as is, however this number may be increased to as many as 32 programmable zones using optional expansion zone modules (EZMs).
  • Page 11: Ul Commercial-Burglary Installations

    WI808F 8/03 Page 11 THIS PAGE INTENTIONALLY LEFT BLANK NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 12: Testing The System

    Note that if the signal strength is less than 3, the keypad will not beep and the strength will be displayed. Except in the Fault-Find Mode, signal strengths less than 3 will be entered into the system log. Upon zone restore, the keypad will beep once. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 13: Wiring Connections

    2.2k Ohm resistor. To connect 8 Ohm Speakers use a Siren Driver with the proper polarity observed. NOTE: Refer to the GEM-P1632 Wiring Diagram for alarm current specification. Note: In NFPA Household Fire Installations. only a single siren or bell can be used on this bell circuit.
  • Page 14: Remote Bus

    Connect a wire with a ground lug crimped or soldered onto one end of the EARTH GROUND screw to the cabinet. NOTE: Grounding connections should avoid bends in the grounding wire whenever possible. NOTE: Do not use a gas pipe, plastic NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 15: Basic Zone Configuration

    ( - ) The basic zone configuration for the GEM-P1632 is 8 zones. Connect as shown above to terminals 13-24. Normally Closed (N.C.) devices may be wired in series or Normally Open (N.O.) devices may be wired in parallel. Use the 2.2K Ohm end-of-line (E.O.L.) resistor in each zone, if selected in programming (refer to the GEM-P1632 Programming...
  • Page 16: 4-Wire Smoke Detectors

    Two-wire smoke detectors can only be connected to zones 7 and 8. To use them, select fire zone programming option and select 2-wire smoke detector programming option for the desired fire zone 7 or 8 (refer to the GEM-P1632 Programming Instructions) and set JP3 to the “2-WF” position as shown. Connect the 2-wire smoke detectors as shown.
  • Page 17: Telephone Lines

    The Telco Line is used by the control panel to dial the central station and for downloading. This line should not be connected to party lines or coin operated telephones. If connected to a line with call waiting, then call waiting interrupt numbers must be programmed into the CS Telephone Numbers (refer to the GEM-P1632 Programming Instructions).
  • Page 18: Keypad Configuration Mode

    A valid number will be acknowledged by a short beep; an invalid number will be rejected by a long beep. 2. Press the button to continue or press the button to exit. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 19 WI808F 8/03 Page 19 Compatibility Number (Not Applicable) THIS FEATURE IS NOT COMPATIBLE WITH THE GEM-P1632 Compat # 0000 CONTROL PANEL. Press the button to continue or press the button to exit. EZM Address EZM Address The keypad's internal EZM (Expansion Zone Module) may be utilized to provide four additional wired zones.
  • Page 20 Cut Jumper B to disable LCD backlighting. DISABLE SOUNDER Cut Jumper to disable the sounder. (Do not disable in UL applications). NAPCO Security Systems, Inc. 333 Bayview Avenue, Amityville, New York 11701 For Sales and Repairs, call toll free: (800) 645-9445 For direct line to Technical Service, call toll free: (800) 645-9440 Internet: http://www.napcosecurity.com...
  • Page 21: Basic Operation

    USER CODES & ZONE DESCRIPTIONS (Refer to the GEM-P1632 Programming Instructions (WI897 and WI1148) for a detailed explanation of programming). Up to 32 personal user codes may be programmed at the keypad. NOTE: The Area Options associated with each User Code may only be programmed in the Dealer Program Mode.
  • Page 22: Arming And Disarming The System

    (Note: The sounder will "pulse" with the GEM-P9600/3200 version 30 and above, and with the GEM-P1632/816 version 10 and above. The sounder will sound a "steady" tone with the GEM-P9600/3200 version 20 and lower, and with the GEM-P1632/816 version 9A and lower). The sounder will emit a pulsing warning tone during the final 10 seconds.
  • Page 23: Instant Arming

    The Manager's Mode, is a low-security mode of operation. It provides quick access to other areas without having to go to another keypad of another area. To arm or disarm the alternate area (for "Classic" keypads): NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 24: Bypassing Zones

    To return to the system, press the button at any time. ACTIVATE BELL TEST Press the NEXT/YES button to activate the burg relay output (while disarmed) for about 2 seconds. If the device does not sound, it may be defective. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 25 Keypad will display the following warning that the system is in Fault Find: "FAULT FIND RF SIG POWER - - " If 24-hour zone is open at end of test, no report is sent (GEM-P1632). If a 24-hour zone is tripped and not restored during Fault Find, when the mode is exited the zone will display as "Faulted"...
  • Page 26: Keypad Messages

    Fire Correct the trouble, then press the button again. alarm condition, followed by one or more zone descriptions. (GEM-P1632 and GEM-P816 panels only). SYSTEM TROUBLE/E51-00 SERVICE Alarm Output SYSTEM TROUBLE - A System Trouble display will be followed by Supervisory.
  • Page 27: Glossary

    Alarm Outputs (See Wiring Diagram for UL requirements.); Alarm Output Duration The GEM-P1632 has three outputs: Alarm (Burg. & Fire), PGM1 and PGM2. The following table summarizes wiring for signaling an alarm in typical installations. See Time Selection for timeout durations.
  • Page 28 After that period has expired, a 15 minute period will count down to Auto-Arm with the sounder pulsing. Auto-Arming may be canceled by arming and disarming the panel. An auto-Arm will be reported as User 33. Auto NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 29 Cancel Window Duration, then an “Attempting to Cancel” will be followed by an “Alarm Canceled” for a successful cancellation. Otherwise, the report had been sent and will be responded appropriately to by the Central Station. Cancel must be NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 30 Alarm Code for Zone 1 is “3”. The communicator will send “1234 31” (Account No. 1234; Alarm, Zone 1). 1400Hz Handshake/Kissoff. 1400Hz Handshake overrides 2300Hz Handshake if both are selected. 2300Hz Handshake/Kissoff. Used with the following receiver formats: Radionics, DCI & Franklin Slow; Radionics Fast. 1400Hz Handshake overrides 2300Hz Handshake if both are selected. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 31 Keypad Report Codes and System Report Codes are transmitted in the same format. Compatible Receivers. The following receivers are compatible with the GEM-P1632: FBI CP220. Formats: Ademco Slow; Silent Knight Slow; Silent Knight Fast; DCI; Franklin Slow; SIA; Radionics Slow; Radionics Fast; Universal High Speed.
  • Page 32 Keypad will display the following warning that the system is in Fault Find: "FAULT FIND RF SIG POWER - - " If 24-hour zone is open at end of test, no report is sent (GEM-P1632). If a 24-hour zone is tripped and not restored during Fault Find, when the mode is exited the zone will display as "Faulted"...
  • Page 33 E19 - Lug E19 is the Listen in Lug. It is an input and when it is forced low the panel will silence the keypad sounder and bell outputs so that the Veri-phone can listen to activity at the residence. See Veri-Phone (WI783): Silence All Outputs During Audio Session. Use Napco Part No. WL1 for field wiring. Easy Exit (Not Evaluated by UL) While armed in the Interior Mode, Easy Exit can be initiated by pressing .
  • Page 34 Fire Verification (Not for use in California.) An alarm on any Fire Zone programmed for “Fire Verification” and connected to the fire power terminal will cause all fire zones to be NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 35 Auxiliary 1 or 2 buttons will cause PGM2 to toggle the current condition of the PGM2 output. Keyfob 1-8 can have their opening / closings reported as users 25 through 32, respectively. Keypad Area Assignments In multiple-area systems, each keypad must be individually configured to the correct keypad number. No two keypads can possess the NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 36 750mS (.75 sec.): The slowest loop-response time, recommended for use with magnetic contacts, window foil, etc. Unless programmed otherwise, loop-response time will be 750mS for all zones. 50mS (.05 sec.): Used for momentary Panic Buttons and area-protection devices, such as photoelectric eyes, passive infrared sensors, floor mats, etc. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 37 To enable, select Pre-Alarm Warning in Zone features and provide an Abort Delay Time of 0 to 254 seconds. Zero results in no delay. Pre-Dial Delay A Pre-Dial Delay may be used whenever a delay is required before dialing. It may be required when programming Dial-Tone Detection, NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 38 RM3008 but has open collector active low outputs in place of relays. The GEM-OUT8 is designed for external remote mounting. One module is needed for the GEM-P1632 Control Panel, although up to 12 may be used. Use the RM3008, RB3008 or...
  • Page 39 DEVICES. Wire 4-wire smokes as shown in the GEM-P1632 Installation Instructions (WI808). Program each zone for Fire. Also program zones for Pulse Alarm Output. If they are of the self-resetting type, 4-wire smokes may be powered from Terminals 25 and 6.
  • Page 40 (or wiring) by limiting the number of alarms a zone may report during a single arming period. NAPCO has this programmable-by-zone feature named Swinger Shutdown, and has been available on its panels for years. The SIA False Alarm Reduction standard CP-01 (to which the panel now complies) requires the SIA definition of "swinger shutdown"...
  • Page 41 Report Trouble is programmed as well. Trouble/Trouble Restore Telco 1/Telco 3 See Report Telco 1/Telco 3 Trouble/Trouble Restore Telco 2 See Backup Report on Telco 2 NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 42 In this case, there will be no indication on the keypad if the zone is tripped. A 24-Hour Zone will be reset when the zone fault has been cleared and the area has been armed and disarmed. Note: Do not program a Day Zone as a 24-Hour Zone. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 43: Standby-Battery Calculation Worksheet

    (Alarm Time) (Box 3) Alarm current drawn in alarm. Alarm Time in Hours. Example: For a 15 minute alarm timeout, Alarm Time = 15/60 = 0.25. MINIMUM REQUIRED BATTERY CAPACITY = BOX 2 + BOX NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 44: Wiring Legend

    Should removal of the circuit board be necessary, use this wiring legend to relocate wire leads to their proper terminals. Enter wire identification number or color code in WIRE NUMBER column and enter wire function in DESCRIPTION column (optional). TERMINAL WIRE NO. DESCRIPTION NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 45: Keypad Programming Modes

    After Test Timer Always TO ARM IN 1-4HRS/PRESS 1-4 TO DELAY AUTO ARM/PRESS 1-4 If Auto Arm? ACTIVATE PROGRAM Always ACTIVATE DOWNLOAD Always N/A means Not Available. Repeat Press button to Exit at any time NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 46: Dealer Mode

    Always If Auto Arm? TO DELAY AUTO ARM/PRESS 1-4 ACTIVATE PROGRAM Always ACTIVATE DOWNLOAD Always N/A means Not Available. EASY MENU PROGRAM Repeat MODE (See Next Page) Press button to Exit at any time NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 47: Easy Menu Mode

    See WI for Info Rcvr Format press . Press again to silence any Enter user code system troubles. XMIT#+CS P KF A XMIT#+CS OP 01 (ZONE DESCRIPTIONS) ** Enter Date** Enter Time ** Dealer Code Repeat NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 48: User Mode

    ZONE DESCRIPTIONS * DATE * TIME * (01-32) * Not avialable in GEM-RP2AS/RP2ASe/RP2ASe2 keypads. To enter Date and Time, GEM-RP1CAe2 keypad (version 6 or greater) must be used. Press button to Exit at any time NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 49 (“01 OUT OF SYSTEM”) Return Jumper JP1 * from Pins 2-3 to Pins 1-2 (“SYSTEM READY”) * JP1 is located at the top center of the circuit board. ** Not available in the GEM-P1632. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 50: Gem-P1632 Wiring Diagram

    Page 50 WI808F 8/03 GEM-P1632 WIRING DIAGRAM LA1469C NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 51: Quick Reference Chart

    · 2 · · · · · ·)* (1062 · 2 )** 0722, Bit 0 Unvacated Premises. Convert from Away to Stay based on no egress through exit door …default is enabled. (GEM-P1632 panel--This feature is Automatic Interior Bypass/ Easy Exit). (0722 1 ·...
  • Page 52 This feature is programmed when "Enable CP-01 Features" is selected in the Easy Programming Menu. At least one Exit/Entry zone must be programmed for each area. (SIA CP-01 Specification 4.2.1) The GEM-P1632 control panel and at least one GEM-RP1CAe2/GEM-K1CA , GEM-RP2ASe2/GEM-K2AS or a GEM-RP3DGTL/GEM-K3DGTL must be installed.
  • Page 53: Factory Default Description

    Page 53 GEM-P1632 FACTORY DEFAULT DESCRIPTION The Factory Program of the GEM-P1632 will change with the release of the new version that complies with Security Industry As- sociation False Alarm Reduction Control Panel-01 Standard (SIA FAR CP-01). Out of Box Panel Operation...
  • Page 54 After exiting the Easy Program Mode, the installer could complete the installation. Subsequent entering of Dealer Program Mode allows only a subset of the Easy Program menu that prevents the existing program from being deleted, but allows the system to be expanded. NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 55: Fcc Statement

    NAPCO Security Systems GEM-P1632 Installation Instructions...
  • Page 56: Limited Warranty

    NAPCO will, within said period, In no event shall NAPCO be liable for an amount in at its option, repair or replace any product failing to excess of NAPCO's original selling price of the product,...