Download Print this page

Mackie MDR24/96 Operation Manual page 30

Operation guide
Hide thumbs Also See for MDR24/96:

Advertisement

(3) PDI•8 cards for MDR24/96
(3) PDI•8 cards for D8B
(1) Clock I/O card for D8B
(3) DB25 to DB25 AES/EBU snakes
(1) 75Ω BNC word clock cable
1. Connect the three AES/EBU cables between the corresponding AES/EBU
connectors on the MDR24/96 and D8B.
2. When AES/EBU is used, the D8B must have a Clock I/O card installed. To
make the D8B the clock master, connect its Word Clock Out to the
MDR24/96 Word Clock In. To make the MDR24/96 the master, connect its
Word Clock Out to the D8B Word Clock In.
1. If the MDR24/96 is the clock master, set the Sample Clock to Internal; if
it is a clock slave, set the Sample Clock to Word Clock and depress the
75Ω termination switch on the Sync card.
2. Set the Sample Rate to 44.1 kHz or 48 kHz according to your preference.
1. If the D8B is the clock master, set the Sample Clock to either 44.1 k
Internal or 48 k Internal; if it is a clock slave, set the Sample Clock to
either 44.1 kHz or 48 kHz. Set the sample rate to match the sample rate
selected on the MDR24/96.

Advertisement

loading