Download Print this page

Mackie MDR24/96 Operation Manual page 14

Operation guide
Hide thumbs Also See for MDR24/96:

Advertisement

The following are recommended setups for establishing proper sample clock
synchronization with the devices connected to the MDR24/96 digital I/O cards.
With the MDR24/96 as a master, connect Word Clock Out of the MDR24/96
to Word Clock In on the receiving device(s). If connecting to older TASCAM
DTRS recorders, use the Sync Out port on the first DIO
Word Clock Out. If there is more than one DTRS recorder in the chain,
connect Sync Out to the word clock input of the first DTRS recorder only; the
other recorders are synchronized through their interconnecting DTRS cables.
With the MDR24/96 operating as a slave to another TDIF device, connect the
word clock output from the master TDIF device to Word Clock In on the
MDR24/96.
With the MDR24/96 as a master, set the receiving device(s) to derive sample
clock from their ADAT Optical ports if the ports are self-clocking. In this
case, no word clock connection is necessary. If the ADAT Optical ports on the
receiving devices are not self-clocking, connect Word Clock Out of the
MDR24/96 to Word Clock In on the receiving device(s).
With the MDR24/96 configured as a slave, connect the word clock out of the
master ADAT Optical device to Word Clock In on the MDR24/96.
With the MDR24/96 as a master, set the receiving device(s) to derive their
sample clock from the AES/EBU ports if the ports are self-clocking. In this
instance, no word clock connection is necessary. If the AES/EBU ports on the
receiving device(s) are not self-clocking, connect Word Clock Out of the
MDR24/96 to Word Clock In of the receiving device(s).
With the MDR24/96 as a slave, connect the word clock out of the master
AES/EBU device to Word Clock In on the MDR24/96.
WARNING
NOT
Termination
Switch
Word clock
input jack
8 card instead of
Word Clock to
other Slaves
BNC-Tee
adaptor
SYNC
Word Clock
From Master

Advertisement