GC Dimensions
Overall Cabinet
Horizontal
A
B
C
Model
Width Depth Height
in.
19.1
34.1
11.0
006-012
cm.
48.5
86.6
27.9
in.
20.1
43.1
17.1
018
cm.
51.1
109.5
43.4
in.
20.1
43.1
17.1
024-030
cm.
51.1
109.5
43.4
in.
20.1
47.1
21.1
036-042
cm.
51.1
119.6
53.6
in.
24.1
54.1
21.1
048
cm.
61.2
137.4
53.6
in.
24.1
54.1
21.1
060
cm.
61.2
137.4
53.6
Condensate is 3/4" IPT copper.
Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection.
Hanger bracket is factory installed
Revisions
LEFT RETURN
Initial 018-030 cabinet
Changed outlet dimensions for larger discharge
Optional 2'
2' [61cm] Service
Changed knockout Dimensions
[61cm]
Access
CSP
Changed Dimensions based upon measured cabinet with Wes
Service
Access
Added 036-042 Cabinet
Front
Added 048-060 and changed 036-042 back to one piece blower corner added second water connection dim
added Small GC
Cleaned up 018 Water Connections
ASP
Straight
Discharge
O
N
BSP
M
Blower
Outlet
P
A
Left Return Back Discharge
ASP
Front
Left Return Straight Discharge
S
Q
T
R
C
Left Return Left View -
Water Connections
Water
1 - In
2 - Out
D
E
F
G
IPT
Size
9.6
0.8
1.8
0.8
1/2"
24.4
2.0
4.4
2.0
15.3
2.4
1.9
2.1
1/2"
38.9
6.1
4.9
5.3
15.3
2.4
1.9
2.1
3/4"
38.9
6.1
4.9
5.3
18.8
2.2
4.7
1.2
3/4"
47.6
5.5
11.9
3.0
19.4
5.9
4.3
2.3
3/4"
49.2
14.9
11.0
5.8
19.4
5.9
4.3
2.3
1"
49.2
14.9
11.0
5.8
Name
RRB
Power Supply
Left Return
3 / 4" [19.1mm] Knockout
1 / 2"
[12.7mm]
Knockout
3.3"
[83.8mm]
Low Voltage
1 / 2" [12.7mm]
Knockout
0.7" [17.8mm]
3
Condensate
Back
3 / 4" IPT
Discharge
Unit Hanger Detail
Model
V
006-012 34.1 [86.6]
C
018-030 43.1 [109.5] 22.2 [56.4] 18.0 [45.7]
036-042 47.1 [119.6] 22.2 [56.4] 18.0 [45.7]
048-060 54.1 [137.4] 26.2 [66.5] 22.0 [55.9]
N
O
Blower
Outlet
M
L
1.75 [44.5mm]
Air Coil
CSP
Front
B
Air Coil Opening
Electrical Knockouts
H
J
K
duct flange (± 0.10 in, ± 2.54mm)
L
1/2" cond
1/2" cond
3/4" cond
Low
Low
Power
Voltage
Voltage
Supply
8.1
5.1
2.1
0.8
20.6
13.0
5.4
1.9
12.1
9.1
6.1
2.6
30.8
23.2
15.6
6.6
12.1
9.1
6.1
2.6
30.8
23.2
15.6
6.6
16.1
13.1
10.1
2.5
41.0
33.3
25.7
6.3
16.1
13.1
10.1
3.7
41.0
33.3
25.7
9.5
16.1
13.1
10.1
1.7
41.0
33.3
25.7
4.4
Date
5/14/01
Legend
5/17/01
CAP=Control Access Panel
5/24/01
CSP=Compressor Service Panel
6/20/01
BSP=Blower Service Panel
7/9/01
ASP=Alternate Service Panel
8/9/01
8/21/03
9/5/03
Right Return
G
1.1 [27.9mm]
F
3.3"
K
2
J
[83.8mm]
H
E
D
CAP
0.7"
[17.8mm]
1
A
Front-View
Condensate
3 / 4" IPT
U
V
W
21.1 [53.6] 16.9 [42.9]
W
U
L
N
BSP
BSP
Blower
Outlet
O
ASP
C
Front

Horizontal Dimensional Data

Discharge Connections
Return Connection
using return air opening
M
N
O
P
Q
Supply
Supply
Return
Return
Height
Depth
Depth
8.9
6.7
5.2
1.3
16.1
22.7
17.0
13.3
3.3
41.0
13.3
9.9
4.1
1.3
23.0
33.8
25.1
10.5
3.3
58.4
13.3
9.9
4.1
1.3
23.0
33.8
25.1
10.5
3.3
58.4
16.1
11.0
3.0
2.5
25.9
40.9
27.9
7.7
6.4
65.8
16.1
13.7
4.1
1.3
35.9
41.0
34.8
10.3
3.2
91.2
18.1
13.7
4.1
1.3
35.9
46.0
34.8
10.3
3.2
91.2
RIGHT RETURN
Front
Straight
Discharge
Back
Discharge
P
N
Blower
C
Outlet
M
O
A
Right Return Back Discharge
CSP
M
Right Return Straight Discharge
Air Coil
Q
B
Right Return Right View -
Air Coil Opening
R
S
T
Height
9.8
1.1
0.6
25.0
2.7
1.5
15.0
1.1
1.0
38.1
2.8
2.5
15.0
1.1
1.0
38.1
2.8
2.5
19.0
1.1
1.0
48.3
2.8
2.5
19.0
1.1
1.0
48.3
2.8
2.5
19.0
1.1
1.0
48.3
2.8
2.5
2' [61cm] Service
Access
Optional 2'
[61cm]
Service
Access
CSP
BSP
Front
S
T
R
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents