Fuel Conversion Instructior - Kenmore Economizer 6 153.333832 Owner's Manual

Mobile home gas water heater
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Step 20.
At arm's length away, set the thermostat
to desired set-
ting. The mark (V) HOT indicative of approx. 120°F is
preferred starting point. If hotter water is desired see the
_Temperature
Regulation" section in this manual.
"A" GAS CONTROl
KNOB
_WARNING
Hotter
water
increases
the risk of scald injury.
Before
changing
temperature
setting
see the
"Temperature
Regulation" section in this manual.
GAS
LINE
Step 21.
Replace the outer door if not replaced in step 17.
Step 22. Remove adhesive label found in conversion kit and
place next to the model raring place. Mark label indi-
cating for which type gas the water heater is now
equipped.
"Fuel"
Conversion
Instructions
From Propane
(L.P.) Gas To Natural
Gas
TEMPERATURE
/'-
PLASTIC CAP
AbJ. DIAL
--
/
g
I
OUT FOR NATURAL
L Figure I ]
IN FOR PROPANE (L._)
A, WARNING
This water heater has been factory equipped to operate
with the type gas indicated in the "EQUIPPED FOR" area
of the model rating plate located near the gas control
valve. The indicated gas may be either Natural
or
Propane (L.P.). By following the conversion instructions in
this manual or the instructions near the g.as control valve,
the water heater must be converted if it is to be used
with the opposite gas. DO NOT USE THIS WATER
HEATER WITH
ANY GAS OTHER THAN THE ONE
LISTED ON THE MODEL RATING PLATE. Failure to use
the correct gas can cause problems which can result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE. If you have any questions or doubts consult
your gassupplier or gas company.
To convert from Propane (L.E) gas to Natural gas, follow the
"Fuel" Conversion
Instructions
From the "Natural Gas to
Propane (L.E) Gas" section except in Step 5, use orifice "E",
marked
NAT.. In Step 6 use pdot orifice G , brass co or and
in Step 8 turn control screw "B_ in Figure 1 clockwise (f'-_)
to stop. Screw must be in "OUT" position for Natural gas.
See "Instruction Label" for orifice sizes.
Maximum Supp,ly Pressure:
10.5 W.C. For Nat. Gas.
13" W.C. for Propane (L.P.) Gas
Minimum Supply Pressure
5 W.C. for Nat. Gas.
11" W.C. For Propane (L.P.) Gas
NUT "K"
_I_UTN
'U_"J"
THERNOCOUPL_E
_
_
PILOT TUBING
[FI B 21 MAN,FOLD
BURNER
, F ,.ii 'ilL
IFig-- ]
17