Download Print this page

Kenmore 141.15227.1 Owner's Manual page 4

Liquid propane gas grill and natural gas grill

Advertisement

Yournatural g asgrillis designed t ooperate on
natural g asonly, a ta pressure o f7"watercolumn
(W.C.) (1/4psi or 1.75kpa),regulated a tthe
residential meter. C heck withyourgasutility
company f orlocal g aspressure a ndwithyour
local m unicipality forbuilding coderequirements. If
yourresidential gaslinepressure h asnotbeen
regulated t o 7"W.C.,contact y ourlocal g asutility
company f orprofessional assistance.
It isrecommended thata Shutoff Valvebeinstalled
atthegassupply source outdoors. Install a ta point
afterthegaspipeexitstheoutside wallandbefore
thequick-disconnect hose, o r install i t atthepoint
before thegaslinepiping enters theground.
SeeFig.
1.
Pipe sealing compound or pipe thread tape resistant
to the action of natural gas must be used on all male
pipe threads when making the connection.
Disconnect your gas grill from fuel source when
the gas supply is being tested at high pressures.
This gas grill and its individual shutoff valve must
be disconnected from the gas supply pipe system
during any pressure testing of that system at
pressure in excess of 1/2 psi (3.5kpa).
Turn off your gas grill when the gas supply is
being tested at low pressures. The grill must be
isolated from the gas supply pipe system by
closing its individual manual shutoff valve during
any pressure testing of the gas supply pipe
system at pressures equal to or less than 1/2 psi
(3.5kpa).
Figure 1 (Natural
gas model only)
TO GRILL
INSIDE
WALL
OUTSIDE
WALL
LOCKING
SHUT
OFF
FITTING
II
i
QUICK
DISCONNECT
GAS
SUPPLY
SHUT
OFF

Advertisement