Installation Instructions
Electrical Connections
ATTENTION
INSTALLER
All electric wall ovens must be hard wired
(direct wired) into an approved junction
box. A plug and receptacle
is NOT permitted
on these products.
DO NOT shorten the flexible
conduit.
The conduit strain relief clamp must be
securely
attached
to the junction
box
and the flexible
conduit must be securely
attached
to the clamp. If the flexible
conduit will not fit within the clamp, do not
install the oven until a clamp of the proper
size is obtained.
NOTE TO ELECTRICIAN:
The 3 power
leads supplied
with this appliance
are
UL recognized
for connection
to heavier
gauge household
wiring.
The insulation
of these 3 leads is rated at temperatures
much higher than the temperature
rating
of household
wiring. The current
carrying
capacity
of the conductor
is governed
by the wire gauge and the temperature
rating of the insulation
around the wire.
WARNING:
Improper
connection
of aluminum
house
wiring to copper leads can
result in an electrical
hazard or fire.
Use only connectors
designed
for
joining copper
to aluminum
and follow
the manufacturer's
recommended
procedure
closely.
Turn off the circuit breaker or remove
fuses to the oven branch circuit.
With the oven supported
on a table or
platform in front of the cabinet opening,
connect the flexible conduit to the
electrical
junction
box as shown below.
Position the conduit
in such a manner
that it will lie on top of the oven in
a natural loop when the oven is
installed.
You will need to purchase
an appropriate
strain relief clamp to
complete
the connection
of the conduit
to the junction
box.
Junction Box
Location
Place oven on a
support to assist in
connecting
conduit
U
Strain Relief Clamp
(not included)
, must be used at
Junction Box
(Continued on following page)