Location Requirements; Electrical Requirements; Water Supply Requirements - KitchenAid W10493416B Use & Care Manual

Table of Contents

Advertisement

Available languages

Available languages

Locat
on Requ
rements
To ensure proper ventilation for your ice maker, the front side
must be completely
unobstructed.
The ice maker may be
closed-in on the top and three sides, but the installation
should allow the ice maker to be pulled forward for servicing
if necessary.
Installation of the ice maker requires a cold water supply inlet
of 1/4"(6.35 mm) OD soft copper tubing with a shutoff valve or
a Whirlpool supply line Part Number 8212547RB, and a
Whirlpool approved drain pump, Part Number 1901A, only to
carry the water to an existing drain.
Choose a well ventilated area with temperatures
above 55°F
(13°C) and below 110°F (43°C). Best results are obtained
between 70°F and 90°F (21°C and 32°C).
The ice maker must be installed in an area sheltered from the
elements, such as wind, rain, water spray, or drip.
When installing the ice maker under a counter, follow the
recommended
opening dimensions shown. Place electrical
and plumbing fixtures in the recommended
location as
shown.
NOTES:
Check that the power supply cord is not damaged, or
pinched or kinked between the ice maker and the
cabinet.
Check that the water supply line is not damaged, or
pinched or kinked between the ice maker and the
cabinet.
Check that the drain line (on some models) is not
damaged, or pinched or kinked between the ice maker
and the cabinet.
34 II
(86.4 cm)
Min.
341/2"
(87.6 cm)
Max.
281/2"
(72.4 cm)
cm)
15"
--4
(38.1 cm)
A. Recommended
location for electrical and plumbing
fixtures
B. Floor level
A
B
Choose a location where the floor is even. It is important for
the ice maker to be level in order to work properly. If needed,
you can adjust the height of the ice maker by changing the
height of the leveling legs. See "Leveling."
Electr
cal Requ
rements
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension
cord.
Failure to follow these instructions can result in death,
fire, or electrical
shock.
Before you move your ice maker into its final location, it is
important to make sure you have the proper electrical
connection:
A 115 volt, 60 Hz., AC only, 15- or 20-amp electrical supply,
properly grounded in accordance
with the National Electrical
Code and local codes and ordinances,
is required.
It is recommended
that a separate circuit, serving only your ice
maker, be provided. Use a receptacle which cannot be turned off
by a switch or pull chain.
IMPORTANT:
If this product is connected to a GFCI (Ground
Fault Circuit Interrupter) equipped outlet, nuisance tripping of the
power supply may occur, resulting in loss of cooling. Ice quality
may be affected. If nuisance tripping has occurred, and if the
condition of the ice appears poor, dispose of it.
Recommended
Grounding
Method
The ice maker must be grounded. The ice maker is equipped with
a power supply cord having a 3 prong grounding
plug. The cord
must be plugged into a mating, 3 prong, grounding-type
wall
receptacle, grounded in accordance with the National Electrical
Code and local codes and ordinances.
If a mating wall receptacle
is not available, it is the personal responsibility
of the customer to
have a properly grounded, 3 prong wall receptacle installed by a
qualified electrician.
Water
Supply
Requ
rements
Check that the water supply lines are insulated against freezing
conditions.
Ice formations
in the supply lines can increase water
pressure and damage your ice maker or home. Damage from
frozen supply lines is not covered by the warranty.
A cold water supply with water pressure of between 30 and
120 psi (207 and 827 kPa) is required to operate the ice maker. If
you have questions about your water pressure, call a licensed,
qualified plumber.
Reverse
Osmosis
Water Supply
IMPORTANT:
A reverse osmosis water filtration system is not
recommended
for ice makers that have a drain pump
installed.
For gravity drain systems only.
The pressure of the water supply coming out of a reverse
osmosis system going to the water inlet valve of the ice
maker needs to be between 30 and 120 psi (207 and
827 kPa).

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ice maker

Table of Contents