Emptying And Cleaning Tanks; Solution Tank; Optional Chemical Metering System - Windsor CS26 Operator Instructions Manual

Hide thumbs Also See for CS26:
Table of Contents

Advertisement

brushes down to further loosen soil. The additional
application of solution will further assist the difficult
cleaning job.
FOR SAFETY: When using machine, go slow on
inclines and slippery services.
Recovery Tank
Lid
Recovery Drain
Hose
Solution Drain
Hose

Emptying and Cleaning Tanks

1. Park the machine next to a floor drain. Drain hoses
are at the front of the machine.
2. Turn the machine power off.
Recovery Tank
1. Open the recovery tank lid. Pull the recovery drain
hose from the mounting bracket. Open cap, then
lower hose in direction of the drain. Do not stand in
front of end of hose. Recovered solution will come
out with force.
2. Flush the recovery tank out with clean water. Do
not use water hotter than 140°F (60°C) to clean
tank. Damage may occur.
3. Clean debris bin.
4. Clean off the float shut-off system and inspect for
free movement of float.
5. Replace the drain hose cap and secure drain hose.
6. If machine is to be stored, leave the recovery tank
lid propped open.

Solution Tank

1. Remove the recovery tank lid.
2. Pull the solution drain hose from its mounting
pocket. Unscrew the cap, then lower hose in direc-
tion of drain.
3. Remove the solution tank cap.
4. Flush the solution tank out with clean water and
run several gallons of clean water through sys-
tems. Do not use water hotter than 140°F (60°C) to
clean tank. Damage may occur.
5. If machine is to be stored, leave solution cap off.
NOTE: Never allow solution to remain in tank.
Damage to tank, seals and valves could occur.

Optional Chemical Metering System

1. Remove chemical container from machine and
store unused chemical. Flush chemical container
with water.
2. Fill chemical container partway with clean water.
Press and hold prime button for 1 minute.
3. Empty chemical container. press and hold prime
button for 30 seconds to purge chemical lines.
Chemical Metering Controls
1. CHEMICAL METERING SYSTEM SELECTION
DIAL (OPTIONAL)
Eight position dial which controls chemical system
operation. Upper five positions turn chemical
system on and controls dilution from .5 to 4.0 oz/
gal. Three lower positions turn chemical system
off.
2. CHEMICAL METERING SYSTEM PRIME
BUTTON (OPTIONAL)
Runs chemical pump when pressed. Press for 30
seconds to prime empty chemical system. Fill
chemical reservoir with clean water and press
prime button for one minute to flush chemical
system.
86367610 Chariot CS26
Operations
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents