Comfort Glow CGD3018N Owner's Operation And Installation Manual page 30

Yellow flame design unvented (vent-free) natural gas log heater 18/24/30" variable manually-controlled 24" thermostatically controlled
Table of Contents

Advertisement

OPTIONAL
POSITIONING
OF
THERMOSTAT
SENSING
BULB
For Masonry and
Factory-built
Metal Fireplace
Continued
U
Thermostat
Sensing Bulb
Mounting Clip
Figure 29. Locating Thermostat Sensing Bulb on Masonry Fireplace
If you have a factory-buih
rneta firep ace, see Figure 30 for location.
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
,I
J
Figure 30 - Locating Thermostat Sensing Bulb on Factory-built Metal Fireplace
If your fireplace has glass doors, position sensing bulb directly behind door gap on right
bottom side (see Figure 31).
Thermostat
Sensing Bulb
Mounting Clip
Glass
Doors
Figure 31 - Installing Thermostat Sensing Bulb behind Glass Doors
5. The mounting
clip must be a minimum of 3" from bottom of fireplace to
prevent crimping
of capillary. Once you have decided on a location, clean the
area thoroughly.
Remove the paper backing from the adhesive on back of
mounting clip. Press the clip into the new location so that the thermostat
sensing bulb will be positioned
vertically with the capillary at the bottom (see
Figure 32). Slide the thermostat
sensing bulb into the clip.
IMPORTANT." Do not crimp capillary,
r
Thermostat
Sensing Bulb
Adhesive-backed
Mounting Clip
t
1/-
Do Not Crimp Capillary
Figure 32 - Positioning the Thermostat Sensing Bulb in the Vertical
Position with the Capillary at the Bottom
_02990