POWER ON/OFF LED (Green)
DOWN command LED (Red)
How to use the hand crank
1. Turn off the POWER switch on the hull unit.
2. Remove gear cover.
3. Attach hand crank to shaft gear or motor gear.
a) When crank is attached to shaft gear
(Requires greater force but less turns.)
Shaft gear
Shaft moves 600 mm
per 120 turns of crank.
8-2
Hand crank
Breaker
Cable gland
POWER
switch
8A
Breaker
(Bottom view)
Hand crank
Tighten screw.
(Use screw from
cover.)
Figure 8-1 How to use the hand crank
Shaft gear
Motor gear
CAUTION
POSSIBILITY OF INJURY
1. If breaker (hull unit) trips do the
following:
1) Turn off power swich on hull unit.
2) Wait 60 sec after breaker has tripped.
3) Press breaker.
2. Turn off hull unit before using hand
crank.
Breaker ON/OFF state
ON
OFF
b) When crank is attached to motor gear
(Requires less force but more turns.)
Motor gear
Tighten screws.
(Use screw from
cover.)
Shaft moves 600 mm
per 210 turns of crank.