Turning The Unit On/Off - Furuno NAVNET 1722 Operator's Manual

Furuno marine radar user manual
Hide thumbs Also See for NAVNET 1722:
Table of Contents

Advertisement

1.3

Turning the Unit On/Off

Press the [POWER/BRILL] key to turn the unit on. A beep sounds and the
equipment proceeds in the sequence shown below, displaying the product
information screen, startup test results and the chart usage disclaimer, in that
order. The startup test checks the ROM, RAM, internal battery and backup data
for proper operation, displaying the results for each as OK or NG (No Good). If
NG appears, an appropriate message appears on the screen. For any NG, try to
press any key to go to the chart disclaimer screen, then perform the diagnostic
test referring to the paragraph "7.5 Diagnostics."
Chart List
Host Name
RADAR PLOTTER
STATION NAME:
RADAR
FURUNO ELECTRIC CO., LTD.
CHARTS AVAILABLE
FLYBRDG = ANB01004
RADAR
= ANB01003
Product information
The magnetron in the antenna unit takes about one minutes and thirty seconds
to warm up before the radar can be operated. The time remaining for warm up of
the magnetron appears at the center of the display, counting down from 1:30 to
0:01.
You may press any key at the chart disclaimer screen to show the last-used
display, or wait several seconds to let the equipment do it for you.
To turn the unit off, press and hold down the [POWER/BRILL] key until the
screen goes dark (approx. 3 sec.). To protect the LCD attach the hard cover.
Note that the network sounder will be turned off approx. three minutes after
turning off the power.
Note: You are asked if you want to start the simulation mode, which provides
simulated operation of the equipment, the first time you turn on the power
(or any time power is applied after a memory reset) the message shown
below is displayed. Push the [ENTER] knob to start the simulation mode,
or press the [CLEAR] key to start normal operation. For further details
about the simulation mode, see the paragraph "1.9 Simulation Display."
STARTUP TEST
ROM
RAM
è
BACKUP DATA
INTERNAL BATTERY
Startup test
START
SIMULATION MODE?
YES ... PUSH ENTER KNOB
NO
... PUSH CLEAR KEY
1. OPERATIONAL OVERVIEW
OK
OK
è
OK
OK
Chart disclaimer
TO SKIP.