Data Boxes Setup - Furuno NAVNET 1722 Operator's Manual

Furuno marine radar user manual
Hide thumbs Also See for NAVNET 1722:
Table of Contents

Advertisement

5. CUSTOMIZING YOUR UNIT
5.5

Data Boxes Setup

You may select the data to show in the data boxes for the plotter, radar and
sounder displays. Six boxes may be displayed in case of small size data box and
two for large size data box.
1. Display the plotter, radar or sounder display, whichever you want to set.
2. Press the [MENU] key to open the main menu.
3. Press one of the following sets of soft keys depending on the display selected
at step 1.
Radar mode: RADAR DISPLAY SETUP, D. BOX
Plotter mode: PLOTTER SETUP, D. BOX
Sounder mode: SOUNDER MENU, D. BOX
4. Use the cursor pad to select an item and then press the EDIT soft key.
5. Select ON or OFF as desired.
6. Press the ENTER soft key or the [ENTER] knob to register your selection. Six
items may be set to ON for small data boxes; two for large data boxes.
7. Repeat steps 4-6 to turn other items on or off.
8. Press the [MENU] key to close the menu
5-20
DATA
BOX
EDIT
RETURN
Data box menu