Performance Data Sheet - Kenmore 106.5113 Series Use & Care Manual

Table of Contents

Advertisement

Available languages

Available languages

PERFORMANCE DATA SHEET
Water Filtration System
Model P5WB2L/P4RFKB2/P4RFKB12
Capacity
200 Gallons (757 Liters)
@
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, and Particulate
Class I*; and against
NSF/ANSI
Standard
53 for the reduction
of Live
Cysts, Asbestos,
Lead, Lindane, Toxaphene,
Atrazine,
and 2,4 - D.
This system
has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below.
The concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to
the permissible
limit for water leaving the system, as specified
in NSF/ANSI
Standards
42 and 53.
Substance Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Minimum %
Average
%
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0 mg/L
2.0 mg/L _+10%
0.20 mg/L
**
97
97.2
Particulate Class I*
85% reduction
7,300,000 #/mL
At least 10,000 particles/mL
75,000 #/mL
99
99.4
Contaminant
NSF Reduction
Average
Influent
Challenge
Maximum
Minimum %
Average
%
Reduction
Requirements
Influent
Concentration
Effluent
Reduction
Reduction
Live Cysts t
99.95%
160,000/L
50,000/L min.
54/U
99.97
99.99
Asbestos
99%
87 MFL
107to 108fibers/U t
0.17 MFL
99
99
Lead: @ pH 6.5
0.010 mg/L
0.160 mg/L
0.15 mg/L + 10%
0.001 mg/L
99.4
99.4
Lead: @ pH 8.5
0.010 mg/L
0.140 mg/L
0.15 mg/L _+10%
0.005 mg/L
98.6
98.6
Lindane
0.0002 mg/L
0.0019 mg/L
0.002 mg/L _+10%
0.00002 mg/L
98.9
99
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 mg/L _+10%
0.001 mg/L
93
93
Atrazine
0.003 mg/L
0.0094 mg/L
0.009 mg/L _+10%
0.0005 mg/L
94.5
94.7
2,4 - D
0.07 mg/L
0.220 mg/L
0.210 mg/L _+10%
0.028 mg/L
87.5
96.1
Test Parameters:
pH = 7.5 _+0.5 unless otherwise
noted.
Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service
capacity
= 200 gallons
(757 liters).
It is important
that
operational,
maintenance,
and
filter
replacement
requirements
be
carried
out
for
the
product
to
perform
as advertised.
Property
damage
can
occur
if all
instructions
are
not
followed.
Use replacement
filter P4RFI<B2/P4RFI<B12, part #9930.
2012 suggested retail price of $49.99 U.S.A./
$59.99 Canada. Prices are subject to change without notice.
Style
1 - When
the water
filter
status display
changes
from
"GOOD"
to "ORDER,"
order
a new filter.
When
the filter
indicator
reads
"REPLACE,"
it is recommended
that you
replace
the filter.
Style 2 -- When
the filter
indicator
changes
from
green
to
yellow,
order
a new filter.
When
the indicator
changes
from
yellow
to red, it is recommended
that you replace
the filter.
Style 3 - When
the filter
indicator
reads
10%, order
a new
filter.
When
the indicator
reads
0%,
it is recommended
that
you replace
the filter.
After
changing
the water
filter,
flush the water
system.
See
"Water
and Ice Dispensers."
These contaminants
are not necessarily in your water supply.
While testing was performed
under standard laboratory
conditions, actual performance
may vary.
The product
is for cold water
use only.
The water system must be installed in compliance
with state
and local laws and regulations.
Do not use with
water
that is microbiologically
unsafe
or of
unknown
quality
without
adequate
disinfection
before
or
after
the system.
Systems
certified
for cyst reduction
may
be
used on disinfected
waters
that may
contain
filterable
cysts.
Refer to the "Warranty"
section
in this Use & Care
Guide
for the Manufacturer's
name,
address
and telephone
number.
Refer to the "Warranty"
section
in this Use & Care
Guide
for the Manufacturer's
limited
warranty.
Application Guidelines/Water Supply Parameters
Water
Supply
Water
Pressure
Water
Temperature
Service
Flow Rate
City or Well
30 - 120 psi (207 - 827 kPa)
33 ° _ IO0°F (0.6 ° - 37.8°C)
0.5 gpm (1.9 Lpm) @ 60 psi
%
*Class I particle size: >0.5 to <1 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
tBased on the use of Cryptosporidium
parvum oocysts
ttFibers greater than 10 um in length
® NSF is a registered trademark
of NSF International.
30

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents