Specifying The Current Switch As A Root Bridge/Secondary Root Bridge - 3Com 4500 Configuration Manual

26/50-port
Hide thumbs Also See for 4500:
Table of Contents

Advertisement

Configuration example
# Configure an MST region named info, the MSTP revision level being level 1, VLAN 2 through VLAN
10 being mapped to MSTI 1, and VLAN 20 through VLAN 30 being mapped to MSTI 2.
<Sysname> system-view
[Sysname] stp region-configuration
[Sysname-mst-region] region-name info
[Sysname-mst-region] instance 1 vlan 2 to 10
[Sysname-mst-region] instance 2 vlan 20 to 30
[Sysname-mst-region] revision-level 1
[Sysname-mst-region] active region-configuration
# Verify the above configuration.
[Sysname-mst-region] check region-configuration
Admin configuration
Format selector
Region name
Revision level
Instance
0
1
2

Specifying the Current Switch as a Root Bridge/Secondary Root Bridge

MSTP can automatically choose a switch as a root bridge through calculation. You can also manually
specify the current switch as a root bridge by using the corresponding commands.
Specify the current switch as the root bridge of a spanning tree
Follow these steps to specify the current switch as the root bridge of a spanning tree:
To do...
Enter system view
Specify the current switch as
the root bridge of a spanning
tree
Specify the current switch as the secondary root bridge of a spanning tree
Follow these steps to specify the current switch as the secondary root bridge of a spanning tree:
To do...
Enter system view
Specify the current switch as
the secondary root bridge of a
specified spanning tree
:0
:info
:1
Vlans Mapped
1, 11 to 19, 31 to 4094
2 to 10
20 to 30
system-view
stp [ instance instance-id ] root primary
[ bridge-diameter bridgenumber [ hello-time
centi-seconds ] ]
system-view
stp [ instance instance-id ] root
secondary [ bridge-diameter
bridgenumber [ hello-time
centi-seconds ] ]
Use the command...
Use the command...
1-18
Remarks
Required
Remarks
Required

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

4500 pwr