Section A: Pilot light will not light (new installation).
Is the manual gas shut-off valve,
/
lbmTurn
the manual gas shut-off valve to
I
located in the supply line to the
_ NO _
the on position and follow the lighting
I
water heater, in the on position?
1
" l instructions on the front of the water heater.
YES
÷
Have you bled all the air "
JWhile repeatedly depressing
the igniter
from the pilot tube and
liNOi_lbutton,
push in and hold the gas control/
gas supp y ne?
1
--Itemperature
knob until the pilot is lit and
maintains a stable flame, (status light
YES
will blink) then release the gas control/
temperature
knob.
i spark?Is
the igniter producing a
iiYEs-_
i
,L
NO
Follow the "Testing the igniter
iSet
to
i
S stem
secton
o ths m anua. I
thermostat
des,red
temperature.
Section B: Pilot light repeatedly goes out.
Remove the burner door
1
assembly. Are the flame-trap and
.Jk
burner free from debris due to
NO,-_,
lexcessiv_e lint, dirt, dust or oil?
YES
Refer to the "Maintenance
of
your Water Heater" section of this
manual for information on cleaning
the flame-trap and burner.
Does the flame-trap
show signs of
discoloration?
pilot remain lit?
YES
÷
Reassemble
the heater and attempt to
return the heater to service. Does the
Shut-off the gas supply to the water heater at
I
I the manual gas shut-off valve, then contact Sears I
I Service at 1-8004-MY-HOME
_ (1-8004694663)
I
Go to section C. i
i Set to desired temperature,
i
NO
"_IP"
Does the diagnostic status light on the i
gas control valve/thermostat give
J
a two flash error code?
YES
Refer to the "Replacing the Pilot/Thermopile
Assemby
nstructons
n the manua.
,L
I
Reassemble
and restore to service, i
Section C: Pilot light will not remain lit.
Check for insufficient
combustion
air. ]
!
Are the combustion
air supply and ventilation openings
of sufficient size? See "Combustion Air Supply and
Ventilation" section in this manual for requirements.
YES
l
•lCorrectsize
of
I
iNOi_lopenings
to allow
Isufficient air.
"F"
iNOiils
ther_ea furnace/air
handler in the same room as the water heater? I
YES
"l"
Does the return air duct for the furnace/
air handier draw its air from a separate
IContact a local Heating,
location than the water heater?
Refer to
• IVentilation,
Air-Conditioning
the "Installation Instructions"
section of
iNOn_&
Refrigeration
authorized
this manual.
|
service provider to correct
|
the combustion
air supply/
YES
/
ventilation
issue.
÷
I Is there proper drafting at the /
/Check
the vent
I
_'
drafthood? See "Draft H°od
_ NO m_4 system f°r restricti°ns/
I
IOperation ' ' section of manual,/
F"Iobstructions a ndcheck
I
yF=S
ithe
vent termination
I
I
/
height. Refer to the
i
i
i"lnstallation
Instructions"
i
isection
of this manual for
I
ispecific
requirements.
I
Contact Sears Service at
1-8004-MY-HOME
®(1-8004694663),
NOTE:
If you are still experiencing
difficulties
after
following
the steps in sections A, B, and C, contact
Sears Service at 1-800-4-MY-HOME ® (1-800-469-4663).