Error Message Resolution Guide
Message
Domain Name Server\nQuery Sending
Error;
Domain Name Server\nQuery Receive
Error;
Domain Name Server\nUnavailable;
Error loading\nparameter file;
Could not open\ntelnet interface;
Could not set\mtelnet options;
Setup file\nsetting mismatch\nReload
Setup;
Display formatting\ntoo large
for\ncurrent screen;
Mobile Unit\ninitialization error;
4-12
Reason
Mobile Unit out of the coverage
area.
Mobile Unit out of the coverage
area.
Could not connect to the DOMAIN
NAME SERVER.
Could not load the parameter file.
Could not Telnet.
Could not use the Telnet
configuration.
Emulation program selected is not
compatible with the configuration
file on the Mobile Unit.
Mobile Unit does not have enough
memory to run your configured
reformatted screens.
Mobile Unit problem.
Solution
Most likely a range, access point, radio,
host or network issue. Troubleshoot the
customer's environment.
Most likely a range, access point, radio,
host or network issue. Troubleshoot the
customer's environment.
Most likely a range, access point, radio,
host or network issue. Troubleshoot the
customer's environment.
Reload the correct configuration files.
Reload the program files.
Reload the correct configuration files.
Remove the emulation and configuration
files. Run clear Telnet on the Mobile Unit
then reload the Mobile Unit with the proper
emulation and configuration files.
Expand the Mobile Unit memory or order a
server from Connect.
Return the Mobile Unit to the manufacturer
for repair.
Supported Equipment Manual
Reference Tech Note
T1113, T1114, T1161,
T1171, T1187 and
T1194
T1113, T1114, T1161,
T1171, T1187 and
T1194
T1113, T1114, T1161,
T1171, T1187 and
T1194
---
---
---
---
---
---
• March, 2006

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bht-7500

Table of Contents