Audio Alarm Verification Connections - Honeywell VISTA 15P - Ademco 6 Zone Control Panel Installation And Operation Manual

Ademco vista series
Hide thumbs Also See for VISTA 15P - Ademco 6 Zone Control Panel:
Table of Contents

Advertisement

Audio Alarm Verification
Connections
(AVS System)
Using the AVS System with AVS Module and AVST Remote Stations
The AVS system provides audio alarm verification via the phone line or via AlarmNet if
the GSMV module is used as the communication device.
Refer to the instructions included with the AVS system for installation procedures. The
following is a summary.
Mounting the AVS Base Unit
As shipped, the AVS Base unit board
comes pre-mounted on its mounting
bracket, which is designed to mount
inside the control cabinet.
Refer to the diagram at right.
a. Position the mounting plate/PC
board assembly in the bottom of
the control's cabinet.
b. Slide the mounting plate to the
right so that the plate's left-hand
tang slides under the cabinet's tie-
wrap loop.
c. Secure the assembly to the cabinet
using the two self-tapping screws
provided.
BATTERY NOTE: When using a 7AH battery, mount the battery vertically on the
bottom left-hand side of the cabinet, with the terminals facing down and right (negative
terminal closest to the PC board bracket).
Wiring the AVS to the Control
The AVS Base unit board has several terminal blocks for making connections to remote
stations, telephone lines, and to the control panel. The AVS base unit connects to the
control's ECP terminals, with all other ECP devices connecting to the AVS base unit ECP
terminals. See the diagram on the next page for specific wiring connections.
DIP Switch: Set the AVS DIP switch to the appropriate address (V15P = 08; V20P = 11).
IMPORTANT: The AVS should be the only ECP device connected to the control's
ECP terminals. Connect all other ECP devices (keypads, expander modules, etc.) to
the ECP terminals on the AVS board.
Connecting an Optional GSMV Module
a. If using a GSMV module for 2-way voice operation, install the module according to its
instructions. NOTE: The module must be mounted within three feet of the control.
b. Connect the audio cable from the GSMV module to the Audio connector on the AVS
board. The audio cable is supplied with the GSMV module.
c. Complete all other GSMV wiring following the instructions included with that
module.
The following summarizes the programming steps for AVS operation (refer to the
Programming Guide for details of the AVS Quick Command options):
a. Install the AVS module according to its instructions.
b. Use one of the control's AVS Quick Program commands as follows :
• installer code + [#] + 03: enable AVS operation without panel sounds on the AVST
• installer code + [#] + 04: enable AVS operation and enable panel sounds on the
AVST speaker
c. Use data field ∗55 Dynamic Signaling Priority to select the desired reporting paths.
Mounting and Wiring the Control
SYSTEM
BATTERY
ON
ON
3
4
5
4
1
2
1
2
3
TANG
BENEATH
MOUNTING
PLATE
SLIDE ASSEMBLY TO RIGHT UNTIL
TANG SLIPS UNDER CABINET LOOP
SECURE
WITH TWO (2)
SELF-TAP SCREWS
(SUPPLIED)
CABINET
TIE-WRAP
LOOP
AVS-003-V0
2-15

Hide quick links:

Advertisement

Table of Contents
loading