Noise reduction settings
Noise reduction reduces the unwanted noise that might be
heard between notes. This setting is made independently for
each program.
HINT: High‐gain amp models are particularly prone to noise,
so we recommend using noise reduction in this case.
1. Hold down the CABINET on/off switch for about one
second to enter OPTION parameter setting mode.
The CABINET on/off switch LED will blink.
2. Turn the MIDDLE control to adjust the noise reduction
sensitivity.
Turning the knob toward the right will increase the
amount of noise reduction.
Turning the knob all the way to the left will turn noise re‐
duction off; it will have no effect.
NOTE: Depending on the guitar you're using, excessively
high settings of noise reduction may cause notes to
be cut off unnaturally.
3. When you've finished adjusting the settings, press the
EXIT/TUNE switch.
14
Using Total Equalizer
Setting the AMP/LINE switch to LINE enables you to use
Total Equalizer, which can adjust the tone of the final sound
output from the ToneLab EX. You can set the following
parameters in OPTION parameter setting mode (p. 3):
• BASS control: Total Equalizer High (EQ HI)
‐10–+10 High range boost amount
• REVERB control: Total Equalizer Low (EQ LO)
‐10–+10 Low range boost amount
• VOLUME control: Trim (TRIM)
‐10–+10 Input level
NOTE: If using Total Equalizer to boost a certain range dis‐
torts sound, adjust the trim setting to lower the input
level.