Troubleshooting Guide - Hamilton Beach HBS1200 - Commercial Revolution Ice-Shaver Blender Operation Manual

Ice shaver/blender
Hide thumbs Also See for HBS1200 - Commercial Revolution Ice-Shaver Blender:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting Guide

Problem . . .
Unit will not run or
stops while it is
running and cannot
be restarted.
Quantity of dispensed
ice is not consistent
Unit is flooding or
water leaking onto
counter
Increased blender
vibration or noise, or
leaking from blender
jar base
Troubleshooting Guide – Status Messages
Displayed Message. . .
BLENDER MOTOR
OVERHEAT—TURN OFF
MAIN POWER SWITCH
INNER HOPPER
NOT IN PLACE
HOPPER LID
NOT IN PLACE
CHECK
DRAIN
CONTAINER CAPACITY
EXCEEDED
JAR NOT IN PLACE
Solution . . .
• Check to see if unit is securely plugged into an electric outlet.
• Check to see if the fuse for the electric outlet has blown or if a circuit breaker
has tripped.
• Check to see if the circuit breaker on the back of the unit has tripped.
• Check to make sure that the ON/OFF switch is in the ON (I) position.
• Check to make sure that the memory card is installed properly.
• Check to make sure that the unit is level and sitting on a solid, sturdy surface.
• Make sure that the end of the drain hose is not under water or blocked.
• Make sure that the drain hose is properly installed and routed. See Preparation.
• Check blade assembly for loose or damaged blades. Replace if necessary.
Solution . . .
• Electric blender motor is too hot. This can be caused when the blender
jar is too full or when blending very thick ingredients. Reduce the
quantity of product in the jar and allow several minutes for the motor
to cool before blending.
• There is a safety interlock on the inner ice hopper. Make sure that the
inner hopper is properly in place.
• There is a safety interlock on the ice hopper lid. Make sure that the lid
is properly in place.
• There is a sensor on the drain that will indicate if water has backed up
in the drain. Check the drain line for blockages or kinks.
• The drink size and number of drinks have exceeded 64 ounces (1.9 L).
• Make sure that the container jar is properly seated on the blender
base. The jar pad sensors prevent the blender motor from starting if
the container jar is not properly seated.
Caring for the Ice Shaver/Blender
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Revolution seriesHbs1400

Table of Contents