Lenovo ThinkServer TS430 User Manual page 166

Machine type: 0387, 0388, 0389, 0390, 0391, 0392, 0393 and 0441
Hide thumbs Also See for ThinkServer TS430:
Table of Contents

Advertisement

10. Install the new power distribution board and cage assembly into the chassis so that the four screw holes
1
in the rear of the new power distribution board and cage assembly are aligned with the corresponding
holes marked with R in the rear of the chassis. Meanwhile, make sure that the two screw holes
the metal clip at the front of the new power distribution board and cage assembly are aligned with the
corresponding holes in the chassis. Then, install the four screws
new power distribution board and cage assembly in place.
Note: Use only screws provided by Lenovo.
Figure 91. Installing the power distribution board and cage assembly
11. Refer to your note and connect the power cables of the new power distribution board and cage assembly
to the system board, all drives, and or hot-swap hard disk drive backplane(s), depending on the model.
Then, properly route the cables and secure the cables with the cable clips and ties in the chassis.
12. Reinstall the front system fan(s). See "Replacing the front system fan" on page 157.
13. Reinstall the hot-swap redundant power supplies and the protective shield for the redundant power
supply bay 2. See "Replacing a hot-swap redundant power supply" on page 148.
14. If you are instructed to return the old power distribution board and cage assembly, follow all packaging
instructions and use any packaging materials that are supplied to you for shipping.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the replacement, go to "Completing the parts replacement" on page 170.
154
ThinkServer TS430 User Guide
1
and the two screws
2
2
in
to secure the

Advertisement

Table of Contents
loading

Table of Contents