v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the Hardware Maintenance Manual to determine which components are customer replaceable units
(CRUs) and which components are field replaceable units (FRUs).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
3108007
System configuration restored to default
settings
3138002
Boot configuration error
3808000
IMM communication failure
3808002
Error updating system configuration to IMM
3808003
Error retrieving system configuration from
IMM
3808004
IMM system event log full
3818001
Core Root of Trust Measurement (CRTM)
update failed
3818002
Core Root of Trust Measurement (CRTM)
update aborted
Action
Information only. This is message is usually
associated with the CMOS battery clear event.
1. Remove any recent configuration changes made
to the Setup Utility.
2. Run the Setup Utility, select Load Default
Settings, and save the settings.
1. Remove power from the server for 30 seconds,
and then reconnect the server to power and
restart it.
2. Update the IMM firmware to the latest level (see
"Updating the firmware" on page 151).
3. Make sure that the virtual media key is seated
and not damaged.
4. (Trained service technician only) Replace the
system board.
1. Remove power from the server, and then
reconnect the server to power and restart it.
2. Run the Setup Utility and select Save Settings.
3. Update the IMM firmware to the latest level (see
"Updating the firmware" on page 151).
1. Remove power from the server, and then
reconnect the server to power and restart it.
2. Run the Setup Utility and select Save Settings.
3. Update the IMM firmware to the latest level (see
"Updating the firmware" on page 151).
v When using out-of-band, use the IMM Web
interface or IPMItool to clear the logs from the
operating system.
v When using the local console:
1. Run the Setup Utility.
2. Select System Event Log.
3. Select Clear System Event Log.
4. Restart the server.
1. Run the Setup Utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
1. Run the Setup Utility, select Load Default
Settings, and save the settings.
2. (Trained service technician only) Replace the
system board.
Chapter 7. Troubleshooting