11. Remove the fan cage assembly (see "Removing the fan cage assembly" on
12. Connect the configuration signal cable. See "Power and signal cables for
13. Complete the cabling of the ServeRAID-BR10i SAS/SATA adapter.
108
ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide
page 46).
internal drives" on page 78 for information about cabling the power and signal
cables.
v For the eight drive-bay, 2.5-inch server model, connect one end of the signal
cable to the drive backplane for drive bays 0 through 3 and route the other
end through the plastic slot on the bottom of the chassis underneath the
front fan cage; then, connect it to the ServeRAID-BR10i SAS/SATA
controller as shown in the following illustrations:
1
Signal cable for drives 0-3
2
Adapter connector for drives 0-3 signal cable
The following illustration shows the connectors on the controller to which
you connect the signal cables from the drive backplanes.
1
ServeRAID-BR10i controller
2
Adapter connector for drives 0-3 signal cable
3
Adapter connector for drives 4-7 signal cable
Connect one end of the other signal cable to the drive backplane for drive
bays 4 through 7 and route the other end of the cable through the plastic

Advertisement