Figure 4.5 Limitation Of Side-Mounting; Table 4.1 Surface Temperature Check Point - Fujitsu MAU3036NC/NP Product/Maintenance Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

Holes for
Mounting screw
3
(3)
Limitation of bottom-mounting
Use all 4 mounting holes on the bottom face.
(4)
Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the disk drive. At designing the system cabinet, consider following points.
Make a suitable air flow so that the DE surface temperature does not exceed 60°C.
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring the surface temperature of specific ICs and the DE. These measurement results
must satisfy the temperature condition listed in Table 4.1.
No.
1
2
3
4
5
4-6
4
1
Use four holes (No.1 to No.4) to mount.
Figure 4.5
Limitation of side-mounting
Table 4.1
Surface temperature check point
Measurement point
Center of DE cover
Read channel LSI
VCM/SPM Driver
HDC
MPU
In case of using a center hole,
2
use it in combination with the
holes of both ends.
Holes for mounting screw
Max. temperature on
package
60°C
80°C
92°C
91°C
88°C
C141-E205