Advertisement

Holes for
mounting screw
3
(4)
Limitation of bottom-mounting
Use all four mounting holes on the bottom face.
(5)
Environmental temperature
Temperature condition at installed in a cabinet is indicated with ambient temperature measured
30 mm from the disk drive. At designing the system cabinet, consider following points.
Make a suitable air flow so that the DE surface temperature never exceed 60°C.
Cool the PCA side especially with air circulation inside the cabinet. Confirm the cooling effect
by measuring the surface temperature of specific ICs and the DE. These measurement results
must satisfy the temperature condition listed in Table 4.1.
No.
1
2
3
4
5
4-6
4
1
Use four holes (No.1 to No.4) to mount.
Figure 4.5
Limitation of side-mounting
Table 4.1
Surface temperature check point
Measurement point
DE surface
Read channel LSI
VCM/SPM Driver
HDC
MPU
2
In case of using a
center hole, use it in
combination with the
holes of both ends.
Holes for mounting screw
Max. temperature on
package
60°C
80°C
92°C
91°C
90°C