Recalibrate (X '10' To X '1F') - Fujitsu MHZ2080BJ Product/Maintenance Manual

Fujitsu computer drive user manual
Hide thumbs Also See for MHZ2080BJ:
Table of Contents

Advertisement

(1)

RECALIBRATE (X '10' to X '1F')

This command performs the calibration. When the device completes the
calibration, the device reports the status to the host system.
This command can be issued in the LBA mode.
Error reporting conditions
(1) An error was detected during head positioning (ST = 51h, ER = 02h).
(2) A SATA communication error occurred (ST = 51h, ER = 14h).
At command issuance (Shadow Block Registers setting contents)
CM
DH
CH
CL
SN
SC
FR
At command completion (Shadow Block Registers contents to be read)
ST
DH
CH
CL
SN
SC
ER
Note:
Also executable in LBA mode
C141-E280
0
0
0
1
x
x
x
x
xx
xx
xx
xx
xx
Status information
x
x
x
x
xx
xx
xx
xx
Error information
5.3 Host Commands
x
x
x
x
xx
xx
5-31