(6)
Cylinder High Field (exp)
The contents of this field indicates high-order 8 bits of the disk-access start
cylinder address.
At the end of a command, the contents of this field are updated to the current
cylinder number. The high-order 8 bits of the cylinder address are set to the
Cylinder High Register.
Under the LBA mode, this field indicates LBA bits 23 to 16. Under the LBA mode
of the EXT system command, LBA bits 47 to 40 are set in the Cylinder High Field,
and LBA bits 23 to 16 are set in the Cylinder High Field (exp).
(7)
Device/Head Field
The contents of this field indicate the device and the head number.
When executing INITIALIZE DEVICE PARAMETERS command, the contents of
this field defines "the number of heads minus 1" (a maximum head No.).
Bit 7
X
- Bit 7: Unused
- Bit 6: L.
- Bit 5: Unused
- Bit 4: Unused
- Bit 3: HS3
- Bit 2: HS2
- Bit 1: HS1
- Bit 0: HS0
C141-E203-01EN
Bit 6
Bit 5
Bit 4
L
X
X
0 for CHS mode and 1 for LBA mode.
CHS mode head address 3 (2
Unused under the LBA mode of the EXT command.
CHS mode head address 2 (2
Unused under the LBA mode of the EXT command.
CHS mode head address 1 (2
Unused under the LBA mode of the EXT command.
CHS mode head address 0 (2
Unused under the LBA mode of the EXT command.
5.2 Logical Interface
Bit 3
Bit 2
Bit 1
HS3
HS2
HS1
3
). bit 27 for LBA mode.
2
). bit 26 for LBA mode.
1
). bit 25 for LBA mode.
0
). bit 24 for LBA mode.
Bit 0
HS0
5-19