User Diagnostics for Windows NIC Driver Management Applications: QLogic QME8242 Mezzanine Card User's Guide
--LinkST
-nR
No control registers test (combine –D or –a)
--noCRegs
-nl
No interrupt test (combine –D or –a)
--noIRQS
-nL
No internal loopback test (combine –D or –a)
--noIntLP
-nH
No hardware test (combine –D or –a)
--noHw
-nS
No link status test (combine –D or –a)
--noLinkSt
-h
View help text
--help
For every test performed, the diagnostic utility shows the following data:
Total number of attempts
Number of successful completions
Number of failures
You can either perform all tests in succession, or perform only specific tests specified by the preceding command-line
parameters.
You can run additional diagnostics in the CLI as listed in the following table. To determine the cna_port_inst, issue the qaucli
-nic –i command as shown in
Table 6. Running Windows Diagnostic Tests in the CLI
Test Type
External Loopback
Flash
Hardware
Internal Loopback
Interrupt
Link
Ping (IPv4)
Register
Transceiver DMI Data

Windows Diagnostic Test Descriptions

file:///T|/htdocs/NETWORK/QLogic/71922/en/diag_win.htm[9/26/2012 4:26:06 PM]
Table
6.
Command
qaucli -nic -extloopback <cna_port_inst> <tests_num> <on_error>
Where <tests_num> specifies the number of tests, 1–65535, and <on_error>> is either
0=Ignore or 1=Abort.
NOTE: This test requires a pass-through module to be configured for both ports. Test
runs between two ports. Single port loopback is not supported.
qaucli –nic –testflash [cna_port_inst]
qaucli –nic –testhw [cna_port_inst]
qaucli -nic -intloopback <cna_port_inst> <tests_num> <on_error>
Where <tests_num> specifies the number of tests, 1–65535, and <on_error>> is either
0=Ignore or 1=Abort.
qaucli –nic –testinterrupt [cna_port_inst]
qaucli -nic -testlink [cna_port_inst]
qaucli -nic -ping <cna_port_inst> <hostname_or_IPv4> [<count> <pocket_size>
<timeout_ms> <TTL>]
Where the default values are count=5, pocket_size=525, timeout_ms=1000, and
TTL=30.
qaucli -nic -testregister [cna_port_inst]
qaucli -nic -trans [cna_port_inst]