PROPANE
For
*For installation of the DC Spark Box refer to the LP Conversion instructions in this manual.

OPTIONAL REMOTE CONTROL

Use the FPI Remote Control Kit approved for
this unit. Use of other systems may void your
warranty.
The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.
1) Choose a convenient location on the wall
to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location. Use Thermostat Wire Table.
2) Connect the wires as per the wiring diagrams
below.
E33 FPI Direct Vent Gas Insert
Units and Units Equipped with DC Spark Boxes*
CAUTION
Do not connect the millivolt
remote control wires
to the 120V wires.
3) Install 3 AAA alkaline batteries in transmitter
and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the
remote receiver to "remote"
mode. The remote control is now ready for
operation.
INSTALLATION
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired,
follow the wiring diagram below. Note: the wires
are connected to the "TH" on the gas valve. Use
the table below to determine the maximum wire
length. FPI offers an optional programmable
thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC
or UL approved may be used.
It is recommended that the thermostat be
installed on an interior wall.
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 120V wires.