Frymaster FOOTPRINT H50 Service And Parts Manual page 11

Pro h50/55-series gas fryers
Hide thumbs Also See for FOOTPRINT H50:
Table of Contents

Advertisement

4. On non-CE fryers only, place the gas valve in the ON position.
5. Place the fryer power switch in the ON position. When the burner has lit and burned steadily for
at least one minute, compare the gas pressure reading to the pressure for the corresponding gas in
the appropriate table below. The tables list the burner manifold gas pressures for each of the gas
types that can be used with this equipment.
6. To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust it to
the correct pressure.
Non-CE
Valve
CE Standard
Burner Manifold Gas Pressures
Gas
Natural Gas Lacq
(G20) under 20 mbar
Natural Gas Gronique *
(G25) under 25 mbar
Natural Gas Gronique
(G25) under 20 mbar
Butane/Propane
(G30) at 28/30 or 50 mbar
Propane
(G31) under 37 or 50 mbar
* Belgian G25 = 7,0 mbar (single or dual)
Non-CE Standard
Burner Manifold Gas Pressures
Gas
Natural
Propane
GAS VALVE REGULATOR CAP
1-6
Pressure (mbar)
Single
Dual
Vat
Vat
7
7
10
10
10
10
17
17
20
20
Pressure
3" W.C.
0.73 kPa
8.25" W.C.
2.5 kPa
CE
Valve