2.5.2.1
Left and Right Over the Filter Pan Contactor Box Configurations cont.
NOTES: Left and right contactor box assemblies are mirror images of one another. With the exception of the
box itself, most components of a left-hand assembly are the same as those in the corresponding right-hand
assembly and vice versa. The configurations illustrated show most possible components, but a particular
configuration may not have all the components shown.
ITEM
PART #
1
106-5488
106-7066
2
823-5736
3
106-5489
106-6819
4
823-5748
5
810-2554
6
807-1947
7
807-0064
8
807-0922
*
221-0482
222-2072
*
222-0482
220-1912
9
807-0070
√ 10
807-1071
√ 11
807-0884
√ 12
807-2284
√ 13
807-2283
√ 14
810-1202
15**
806-8674
16**
806-8673
√ 17
826-1562
18
807-2749
19
807-0037
20
807-2278
21
106-6204
22
807-0922
*
221-0610
*
222-0610
*
807-0012
* Not illustrated.
** Full Vat has three relays 826-1562, Dual-Vat has six relays.
√ Recommended parts.
Box Assembly, Left Contactor Standard (Over the Filter Pan)
Box Assembly, Left Contactor Fryer ½ Half Fryer on Left
Box Assembly, Left Contactor EPRI (Over the Filter Pan)
Box Assembly, Right Contactor Standard (Over the Filter Pan)
Box Assembly, Right Contactor Fryer ½ Half Fryer on Right
Box Assembly, Right Contactor EPRI (Over the Filter Pan)
Plug, Cord Cutout 1.125 Button
Plug, .875 Diameter Dome
Transformer, 480V/120V 150VA
Holder, Bus Fuse
Cover, Left Hand Standard Contactor Box
Cover, Left Hand Fryer ½ Half fryer on Left
Cover, Right Hand Standard Contactor Box
Cover, Right Hand Fryer ½ Half fryer on Right
Terminal, Ground Lug
Contactor, 24V 30 Amp Mercury
Contactor, 24V 50 Amp Mercury
Contactor, 24V 50 Amp Mechanical
Contactor, 24V 63 Amp Mechanical
Contactor, 24V 40 Amp Mechanical
Heatsink Assembly, DV Solid State Relay
Heatsink Assembly, FV Solid State Relay
Components of Items 15 and 16
Kit Relay, Solid State 40 Amp 280V with Heatsink
Heatsink, Solid State
Terminal, ¼-inch Push-on
Fuse, 20 Amp
Filter Assembly, EPRI
(used in CE WYE-configured EPRI units only)
Holder, Bus Fuse
Bracket, Left Hand Contactor Box Mounting
Bracket, Right Hand Contactor Box Mounting
Relay, Tilt Switch 18 Amp 1/3 HP 24 V Coil
COMPONENT
(only in 14kW & 17kW units)
(only in 22kW units)
(See components below)
(See components below)