Frymaster FOOTPRINT 8196345 Service & Parts Manual page 12

Gas fryers
Table of Contents

Advertisement

6. To adjust the burner gas pressure, remove the cap from the gas valve regulator and adjust to the
correct pressure.
Non-CE
Valve
7. Place the fryer power switch (and the gas valve in non-CE fryers) in the OFF position. Remove
the fitting from the pressure tap hole and reinstall the pressure tap plug.
CE Standard
Burner Manifold Gas Pressures
Gas
Natural Gas Lacq
(G20) under 20 mbar
Natural Gas Gronique *
(G25) under 25 mbar
Natural Gas Gronique
(G25) under 20 mbar
Butane/Propane
(G30) at 28/30 or 50 mbar
Propane
(G31) under 37 or 50 mbar
* Belgian G25 = 7,0 mbar
Non-CE Standard
Burner Manifold Gas Pressures
Gas
Natural
Propane
GAS VALVE REGULATOR CAP
1-6
Pressure
(mbar)
Single
Vat
7
10
10
17
20
Pressure
3" W.C.
0.73 kPa
8.25" W.C.
2.5 kPa
CE
Valve

Advertisement

Table of Contents
loading

This manual is also suitable for:

Protector footprint pro series

Table of Contents

Save PDF