7.4 Replacement of burner
Isolate the boiler from the electrical
supply.
Remove front casing as in section
7.1.3.
Remove combustion chamber cover
as in section 7.1.5
Disconnect the ignition and flame
sensing electrode leads (1, fig. 57).
Remove two screws (2, fig 57) and
pull burner forwards to remove.
Reassemble in reverse order.
Carry out electrical checks (see
section 5.1) and check burner
pressure (see section 5.8) and gas
rate.
7.5 Replacement of electrodes
Isolate the boiler from the electrical
supply.
Remove front casing as in section
7.1.3, and remove combustion
chamber cover as in section 7.1.5
Remove heat exchanger front panel
as in section 7.1.7
Pull off HT lead (ignition electrode)
or sensing wire (flame sensing
electrode) (1, fig 57)
Depress spring retaining clip (1, fig
58) gently pull electrode up and
clear of burner.
To replace the electrode, depress
spring retaining clip (1, fig 58) and
insert electrode until the "V" locates
in the cross support (2, fig 58)
Carry out electrical checks (see
section 5.1).
2
1
fig. 58
fig. 57
5
4
2
3
1
6
35