8. Fault finding

8.1 Introduction

The TURBOmax has built in diagnostic
indicator lights (fig. 77) to assist you
with fault finding in the unlikely event
of a boiler malfunction. The lights will
illuminate in sequence, indicating the
operational status of the boiler.
Should a fault develop in the boiler
the indicators may flash highlighting
the possible fault e.g.
Power on indicator (green)
Illuminates when the electricity supply
to the boiler is on, the main on/off
control is set to position ( ) and the
internal boiler fuses are o.k.
(A flashing indicator shows that the
overheat thermostat has cut out.)
Hot water demand indicator (yellow)
Illuminates whenever there is a
demand for hot water i.e. a hot water
tap is opened.
Central heating demand indicator
(yellow)
Illuminates whenever there is a
demand for central heating i.e. the
central heating control is set to
position (
) and the external
heating controls are calling for heat.
Note: If the external controls are not
calling for heat (i.e. the room
thermostat has reached temperature)
this indicator will go out. This is
perfectly normal.
Fan operation indicator (yellow)
Illuminates to indicate that the fan is
operating and has been checked by
the fan pressure switch.
(A flashing indicator shows that the air
pressure switch has not made.)
Ignition indicator (yellow)
Illuminates when gas valve, operator
and ignition transformer are
energised. This indicator remains on
during burner operation.
(A flashing indicator shows lack of
water or poor water circulation in cen-
tral heating system.)
44
Flame indicator (yellow)
Illuminates when flame is recognised
by the flame monitoring system.
(A flashing indicator shows that the
NTC sensor is broken, not connected
or shorted to earth.)
Burner lockout indicator (red)
Illuminates if the burner fails to light
within 9 seconds of illumination of the
ignition indicator after the 2nd igniti-
on cycle.
(A flashing indicator shows a failure
in the electronic boards.)
To reset the appliance after a lockout
(either burner lockout illuminated or
any other indicator light flashing), turn
the central heating control to the reset
position ( ) and release.
8.2 Logical fault finding
procedure
8.2.1 Preliminary Checks
These checks must be carried out
before attempting to use the fault
finding guide:-
1) Carry out electrical safety checks
(see Section 5.1: Preliminary
electrical checks).
2) Check that the external electricity
supply to the boiler is on, and a
supply of 230 V~ is present
between boiler terminals 'L' and
'N'.
3) Check that gas supply to the boiler
is on and that it has been correctly
purged (see Section 5.2: Gas
Supply).
7
6
5
4
3
7
6
5
4
3
fig. 77
4) Ensure the heating system is full of
water and charged to approx.
1 bar. If not refill the system and
vent (see section 5.4: Filling the
heating system). Ensure boiler flow
and return service valves are open.
5) Check that boiler main on/off
control is set to position ( )
6) Set boiler central heating control to
Heating and Hot Water position
(
7) Ensure that the Maximum Radiator
Temperature and Maximum Hot
Water Temperature controls are set
to position '9'.
8) Check that all the external controls
are on and calling for heat (if no
external controls are fitted, boiler
terminals 3 and 4 must be linked).
Check that boiler anti-cycling
'economiser' control is not engaged
(see Section 4.8.5).
8.2.2 Procedure
Note: Always check the operation of
the boiler for central heating first
before checking hot water operation.
Do not open a hot tap unless
instructed to by the fault finding guide.
8
9
1
2
8
9
1
2
)
60
30
90
0°C
120
4
0
bar
3
1
2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Turbomax vuw 242 eTurbomax vuw 282 e

Table of Contents