Final Flush Of The Heating System ("Hot") - Vaillant ecoTEC plus SERIES Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

10
Start-up
S.24
DHW mode
Burner on
Back
10.11 Display during cylinder charging (VU boilers only)
> If you have connected the controller for the heating
installation using a two-wire eBUS line, then set the hot
water temperature at the boiler to the maximum possible
temperature (¬ table 11.1).
> Adjust the target temperature for the connected domes-
tic hot water cylinder to the controller.
10.13

Final flush of the heating system ("hot")

> Operate the appliance until the boiler and the heating
system are up to temperature.
> Check the heating system for leaks.
> Connect a hose to the drain valve located at the lowest
position of the heating system.
> Shut off the boiler, open the drain valve and all purging
valves on the radiators and allow the water to flow out of
the heating system and the boiler quickly and fully.
> Close the drain valve.
> Fill the heating system again with water as described in
¬ section 10.7.3.
> Re-fill the system until the system design pressure of
0,1 MPa (1,0 bar) is attained. (The actual reading on the
digital pressure gauge should ideally be 0,05 MPa (0,5
bar) plus an additional pressure corresponding to the
highest point of the system above the base of the boiler
– 10 m head equals an additional 1 bar reading on the
pressure gauge. The minimum pressure should not be
less than 0,1 MPa (1 bar) in any installation.) If the system
is to be treated with an inhibitor it should be applied at
this stage in accordance with the manufacturer's instruc-
tions. Further information can be obtained from Sentinel,
Betz Dearborn Ltd., Tel: 0151 420 9595, or Fernox, Alpha–
Fry technologies. Tel: 0870 8700362.
> Refit the boiler casing (¬ section 4.7).
> Attach the bottom cover to the boiler by sliding the front
edge of the cover into the lip at the bottom front edge of
the appliance chassis.
> Carefully push the rear of the bottom cover upwards
until the spring retaining clips engage at the side of the
appliance. It may be necessary to adapt the bottom
cover by removing the easy break sections.
48
Installation and maintenance instructions ecoTEC plus 0020116700_01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents