Installation; Type Plate - Vaillant ecoTEC SERIES Instructions For Installation And Servicing

Wall hung room sealed fan assisted condensing boiler
Hide thumbs Also See for ecoTEC SERIES:
Table of Contents

Advertisement

2.3

Installation

14
13
12
11
10
Fig. 2.2 Function elements of combination boilers
Legend:
1
Expansion vessel
2 Air intake pipe
3 Burner module
4 Ignition electrode
5 Fan
6 Diverter valve with by-pass
7 Pump
8 Aqua-Sensor
9 Electronics box
10 Hot water heat exchanger
11 Gas valve
12 Pressure sensor
13 Heat exchanger
14 Flue pipe connection
2.4

Type plate

The type plate of the Valliant ecoTEC is attached to the
bottom of the appliance at the factory.
Instructions for installation and servicing ecoTEC 839592_12
14
1
13
2
3
4
5
12
6
11
7
8
9
Fig. 2.3 Function elements of system boilers
Legend:
1
Expansion vessel
2 Air intake pipe
3 Burner module
4 Ignition electrode
5 Fan
7 Pump
9 Electronics box
11 Gas valve
12 Pressure sensor
13 Heat exchanger
14 Flue pipe connection
Boiler specifications 2
1
2
3
4
5
7
9
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents