MODEL
HTI-300AF
HTI-400AF
HTI-500AF
HTI-3060AF
Units are shipped from the factory wired 3ø, and are field convertible to 1ø.
Field wiring for 3ø must be at least 10 ga. copper.
Field wiring for 208 volt 1ø must be at least 8 ga. copper.
Field wiring for 240 volt 1ø must be at least 6 ga. copper
Field wiring for all units must suitable for at least 90ºC.

TABLE OF CONTENTS

WARRANTY
SPECIFICATIONS
INTRODUCTION
ELECTRICAL SPECIFICATIONS
VOLTS
WATTS
208
6000
240
8000
208
9000
240
12000
208
9000
240
12000
208
9000
240
12000
AMPS PER LEG 3ø
L1
L2
24.9
14.4
28.8
16.7
25.0
25.0
28.9
28.9
25.0
25.0
28.9
28.9
25.0
25.0
28.9
28.9
1
xi
1
2
4
5
6
8
9
11
12
13
13
AMPS 1ø
L3
14.4
28.8
16.7
33.3
25.0
43.3
28.9
50.0
25.0
43.3
28.9
50.0
25.0
43.3
28.9
50.0