Raster Box

The Raster Box menu item allows the user to overlay a border on the Main or Preview output images. To control the
display of the Raster Box, scroll to the Raster Box menu line, select the menu item with the Select key and then turn
the Adjust control to select the desired output (Preview, Main, Both, or Off). The Off selection is used to disable the
display of the Raster Box. The raster box can be displayed on the test patterns or over live data.

Display Lock

Display Lock is an optional feature that allows multiple ScreenPro units to have their outputs synchronously locked
together. This is achieved by having one ScreenPro act as a master timing unit. The other ScreenPros are slaved to
the master unit and lock their output timing to the master unit. See the diagram below for help in connecting units
together.
After connecting the units together, go to the Output menu on each unit. Make sure the FORMAT and FRAME RATE
fields are the same for each system. Finally, go to the DISPLAY LOCK field and make sure the Master unit is set to
Manual # 26-0002901-00 / Revision H
ScreenPro
Master
Display Lock = OFF
Display Lock IN
Display Lock OUT
ScreenPro
Slave
Display Lock = ON
Display Lock IN
Display Lock OUT
ScreenPro
Slave
Display Lock = ON
Display Lock IN
Display Lock OUT
Display Lock Connection Diagram
ScreenPro - High Resolution Seamless Switcher