_K==oÉãçíÉ=`çåíêçä
Remote Commands
f_oq
f`abi=
f`kq
f`mel
128
Parameters:
-i (input):1 - 9
-m (mode): 0 - input not available, 1 - input available
Query Format: IAVAIL -i (input) -?
Query Response: IAVAIL -i (input) -m (mode)
Description: Input Brightness Adjust
Command Format: IBRT -i(input) -b (bright)
Parameters:
-i (input): 1-9
-b (bright): 75.0% - 125.0% (Default: 100%)
Query Format: IBRT -i (input) -?
Query Response: IBRT -i (input) -b(bright) --min 75 --max 125
Description: Deletes input configuration.
Command Format: ICDEL -i(input) -f(file)
Parameters:
-i(input):1 - 9
-f(file): 1 - 64. If specified, update the File Association menu to reflect the
selected file number. If not specified, use the current file number from the
ICREC query.
Query Format: N/A
Query Response: N/A
Description: Input Contrast Adjust
Command Format: ICNT -i(input) -c(contrast)
Parameters:
-i (input): 1-9
-c (contrast): 75.0% - 125.0% (Default: 100%)
Query Format: ICNT - i(input) -?
Query Response: ICNT -i(input) -c(contrast) --min 75 --max 125
Description: Input Phase Adjust. This command is only valid for analog input
types.
Command Format: ICPHO -i(input) -a(ADC) -p(phase)