EAW DX1208 Help File page 51

12x8 digital mixer and signal processor
Hide thumbs Also See for DX1208:
Table of Contents

Advertisement

Parameters
Preset Name
Selected Preset
Load
Store
Clear
Set
Power-On Default Displays which of the 24 available Presets will be automatically
Permissions
Description
The DX1208 can be secured against unauthorized use by requiring users to log into the
hardware to gain access to Device Windows. The DX1208 supports two user access levels,
called Permissions: Administrative and User. Administrative Permission grants the user full
Each Preset can be given a user-defined name of up to 16
characters in length. When a Preset is loaded, the name of the
loaded Preset appears in the Preset Name text box; when a
Preset is stored, the name currently in the Preset Name textbox is
stored into the Selected Preset along with the other DX1208
parameter settings.
Selects the Preset that will be used for Load, Store, Clear, and Set
operations.
Loads the parameter values stored in the Selected Preset into
active memory. After pressing Load, the Preset Loading progress
dialog appears, showing the number of the Preset being loaded,
and whether or not the Preset was triggered locally or remotely.
Preset loads usually take several seconds to complete while the
current device parameters are updated to the new values.
Stores the current values of all device parameters (except where
noted above) as well as the Preset Name into the Selected
Preset.
Erases the Selected Preset, and marks the cleared Presets as
'(default)' in the Selected Preset list. Loading a cleared Preset
resets the unit to a factory default state.
Makes the Selected Preset the Preset that is automatically loaded
when the unit is powered on.
loaded when the unit is powered on. If the Power-on Default
Preset has been cleared, then the unit will be reset to the factory
default state on power up.