AGC Enable
•
Bypass Compressor
EQ
Description
Each of the twelve DX1208 Input Channels is equipped with a fully-configurable six-band EQ,
which occurs in between the Compressor and the Ducker in the DX1208 signal chain. Each
EQ band can configured as a parametric, high/low pass, or shelving filter, and can be
individually enabled or disabled.
Parameters
•
Selected
•
Type
•
Frequency
In practice the Ratio determines how aggressively the AGC tries to drive
the output volume toward the Target.
Toggles the process between Compressor and AGC operation.
Bypasses the AGC without changing the AGC's settings.
Determines which Filter the Type, Frequency, Gain, BW/Q, and
Bypass Filter settings apply to.
Sets the Filter type of the Selected filter from amongst the
following choices: [Parametric], [6dB Low shelf], [6dB High Shelf],
[12dB Low Shelf], [12dB High Shelf], [12dB Low Pass], [12dB
High Pass.]
Sets the Frequency center of the Selected Filter. Frequency
values range from [20 Hz] to [20 kHz].
28