Control units
(cont.)
– Set room temperatures for standard mode (day temperature) and
reduced mode (night temperature) via the standard display
– Heating program, switching times for heating circuits, DHW heat-
ing and DHW circulation pump plus further settings via plain text
menu on the display
■ Party and economy mode can be enabled via the menu
■ Only for heating circuit with mixer:
Room temperature sensor for room temperature hook-up
Note
For room temperature hook-up, the Vitotrol 300A must be installed
in the living space (lead room).
Installation location:
■ Weather-compensated mode:
Installation anywhere in the building.
■ Room temperature hook-up:
Installation in the main living room on an internal wall opposite radi-
ators. Never install inside shelving units, in recesss, or immediately
by a door or heat source (e.g. direct sunlight, fireplace, TV set, etc.).
The integral room temperature sensor captures the actual room
temperature and effects any necessary correction of the flow tem-
perature as well as a quick heat-up at the start of the heating oper-
ation (if suitably encoded).
Connection:
■ 2-core lead, length max. 50 m (even if connecting several remote
control units)
■ Never route this lead immediately next to 230/400 V cables
■ LV plug as standard delivery

Room temperature sensor

Part no. 7438 537
Separate room temperature sensor as supplement to the Vitotrol
300A; to be used if the Vitotrol 300A cannot be installed inside the main
living room or in a suitable position where the unit could capture and
adjust the temperature.
Installation in the main living room on an internal wall opposite radia-
tors. Never install inside shelving units, in niches, or immediately by a
door or heat source (e.g. direct sunlight, fireplace, TV set, etc.).
Connect the room temperature sensor to the Vitotrol 300A.
Connection:
■ 2-core lead with a cross-section of 1.5 mm
■ Lead length from the remote control up to 30 m
■ Never route this lead immediately next to 230/400 V cables
8 0
7

Mounting base for programming unit

Part no. 7299 408
To be able to freely position the programming unit of the control unit
anywhere outside the appliance.
VIESMANN
84
Specification
Power supply via KM BUS
Power consumption
Protection class
IP rating
Permissible ambient temperature
– during operation
– during storage and transport
Set room temperature range
Specification
Protection class
IP rating
Sensor type
Permissible ambient temperature
– during operation
– during storage and transport
2
(copper)
To be fitted directly to the wall or a surface box.
Distance from the boiler: Observe the lead length incl. plugs of 5 m.
1 5
5
0.5 W
III
IP 30 to EN 60529;
ensure through appropri-
ate design/installation
0 to +40 °C
−20 to +65 °C
3 to 37 °C
III
IP 30 to EN 60529;
ensure through appropri-
ate design/installation
Viessmann NTC 10 kΩ at 25 °C
0 to +40 °C
−20 to +65 °C