Design information
Pre-installation for installing the Vitodens 200-W directly onto a wall (single boiler)
An installation template is supplied with the Vitodens 200-W for the
location of fixing holes for the wall mounting bracket and the location
of the flue pipe on the wall.
Order connection sets separately for the connection of the heating cir-
cuits and one DHW cylinder.
4
A Reference point Vitodens top edge
B Installation template Vitodens
C Area for supply cables.
Allow all cables/leads to protrude approx. 1200 mm from the
wall.
Installation in front of a wall with a self-supporting mounting
frame (single boiler)
The Vitodens can be mounted on the self-supporting mounting
frame.
Pre-installation, multi boiler system
Hydraulic cascade
Flow and return collectors, optionally with low loss header, for multi
boiler systems of 2 to 8 boilers in series or 4 to 8 boilers arranged in a
block formation. Heating circuit connections either on the right or left.
VIESMANN
28
(cont.)
4 8
0
4 2
2
Ø 10
E
C
2 0
0
A
B
F
D Recommended dimension: 1975 mm
E Wall mounting bracket
F Top edge finished floor
The mounting panel supplied with the boiler cannot then be used.
Order the low loss header or the heating circuit connecting kit as sep-
arate accessories.
VITODENS 200-W