FortiSwitch-5003A configurations

Front panel connectors

FortiSwitch-5003A configurations

Base and fabric gigabit switching within a chassis

14
Table 5: Fabric network activity LEDs
Fabric network
Interface or connection
activity LED
2/1
Fabric channel connection between fabric channel 1 and fabric
channel 2. This LED is lit if there are two FortiSwitch-5003A boards
installed in the chassis to indicate fabric backplane communication
between them.
3 to 13
Fabric backplane connection to FortiGate-5000 boards in chassis slots
3 to 13.
Table 6
lists and describes the FortiSwitch-5003A front panel connectors.
Table 6: FortiSwitch-5003A connectors
Connector Type
Speed
MGMT
RJ-45 10/100/1000
Base-T
COM
RJ-45 9600 bps
8/N/1
B1, B2
RJ-45 10/100/1000
Base-T
BASE 10G SFP+ 10 Gbps
FABRIC
SFP+ 10 Gbps
10G, 14/F8,
F7, F6, F5,
F4, F3, F2,
F1
You can operate the FortiSwitch-5003A board as a fabric and base channel
layer-2 switch for any FortiGate-5000 board. The FortiSwitch-5003A board is
compatible with all FortiGate-5000 boards.
Figure 4
shows a FortiGate-5050 chassis with a FortiSwitch-5003A board in slot 1
and two FortiGate-5001A boards in slots 3 and 4. In this configuration the
FortiGate-5001A boards are using base channel 1 for HA heartbeat
communication. The FortiGate-5001A boards use base1 as the HA heartbeat
interface.
FortiSwitch-5003A and 5003 Fabric and Base Backplane Communications Guide
Protocol
Description
Ethernet
Copper gigabit connection to out of band
management interface.
RS-232
Serial connection to the command line
serial
interface.
Ethernet
Copper gigabit connection to the base
backplane channel.
Ethernet
SFP+ 10 gigabit connection to the base
backplane channel.
Ethernet
SFP+ 10 gigabit connection to the fabric
backplane channel.
FortiSwitch-5003A system