FortiGate-5140 chassis
FortiGate-5140-R Chassis Guide
01-30000-87705-20090108
http://docs.fortinet.com/
Feedback
The FortiGate-5140 shelf managers control chassis power up and power down, chassis
power distribution, monitor chassis operating parameters, monitor and control chassis
cooling, and can signal alarms if the chassis encounters problems. All FortiGate-5000
modules installed in the chassis communicate with the shelf managers.
The FortiGate-5140 shelf managers are factory installed. In most cases users do not have
to install or configure the shelf managers.
Each shelf manager has two ethernet interfaces (ETH 0 and ETH 1). You can connect to
ETH 0 from the shelf manager front panel. ETH 1 connects to the FortiGate-5140
backplane.
The shelf managers detect alarm conditions and communicate alarm signals to the
FortiGate-5140 shelf alarm panel. The shelf alarm panel also contains serial interfaces for
connecting to the shelf managers.
The shelf managers are hot swappable. You can remove a shelf manager by opening the
extraction lever until the hot swap LED starts blinking. When the hot swap LED turns solid
blue you can remove the shelf manager from the FortiGate-5140 chassis.
Figure 3: FortiGate-5140 shelf manager front panel
Reset
ETH 0 and 1 network
activity LEDs
Button
5000SM
10/100
link/Act
10/100
link/Act
Retention
ETH0
Status
Screw
100base-T
LEDs
Ethernet
Table 2: FortiGate-5140 shelf manager LEDs
LED
State
ETH 0
10/100
Yellow
ETH 1
link/Act
Green
Off
STATUS
Green
Red
HOT SWAP
Off
Blue
Long blink
Short blink
Hot Swap
LED
Handle
Description
The Ethernet interface is connected at 100 Mbps.
Blinking LED indicates network traffic.
No link.
This shelf manager is operating normally as the active shelf
manager. Usually the primary shelf manager operates as the
active shelf manager.
This shelf manager is operating normally as the backup shelf
manager. Usually the secondary shelf manager operates as the
standby shelf manager.
The shelf manager is not ready to be removed.
The shelf manager is ready to be removed.
The shelf manager is starting up after being inserted into the
chassis.
The shelf manager is shutting down in preparation for being
removed from the chassis.
FortiGate-5140 shelf managers
9