2.6 Amplifier Protection

Ashly Pema amplifiers have the following protection circuits:
Over Current Protection - When the output current exceeds the amplifier's safe operating limits. This occurs in the
amplifier output stage.
Thermal Protection - When the internal temperature is below 40°C the fan runs at its slowest speed. Above 40°C the
speed is increased until it reaches its maximum value. If the temperature exceeds 100°C, the input on that channel is reduced.
If the temperature exceeds 120°C, the power supply is switched off.
Mains Protection – Protection within the power supply includes: In-rush Current Limitation during power up, Mains
Over Voltage Detection, and internal Mains Fuse Protection. To protect the Mains fuse against AC overcurrent due to excessive
audio output current, there is a protection scheme indicated on the amplifier front panel and in Protea
audio output level until the overcurrent condition is no longer present.
ne

3. PROTEA

CONTROL SOFTWARE

3.1 Installing Software

Ashly Protea
software is included on a CD with each unit. Check the Ashly web site at www.ashly.com for the latest
ne
software release. Autorun will launch the application ProteaSystemSoftwareNE to install the Protea
3.1a Using Protea
Software
ne
Once the software has been installed on the computer and Ethernet connections have been made successfully, launch
the software. All Ashly Pema and NE devices installed on the network will be automatically detected and shown in the active
device listing "device tree" on the left side of the Protea
all Ashly devices currently installed on available networks, also including any devices which have been formerly installed but
are now off-line.
Device icons can be dragged onto the project canvas from the menu tree, or placed as virtual devices in "Design Mode".
In other words, a device icon on the canvas is not necessarily a live product. It may be a virtual device, or a device that is cur-
rently off-line. In the device tree, all currently connected and active devices are highlighted in green. Ashly devices which have